Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA vs Trust Oxxtron 1000VA UPS with standard power outlet

Add a product
  • 11specifications compared
  • 9differ
  • 2identical
  • 30known for one product only

Key differences

The CyberPower OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA has 0.5 kVA more output power capacity than the Trust Oxxtron 1000VA UPS with standard power outlet (1.5 kVA vs 1 kVA). The CyberPower OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA has 340 W more output power than the Trust Oxxtron 1000VA UPS with standard power outlet (900 W vs 560 W). The CyberPower OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA has 338 mm more width than the Trust Oxxtron 1000VA UPS with standard power outlet (433 mm vs 95 mm). Power protection features: Overload on the CyberPower OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA, Overload, Short circuit on the Trust Oxxtron 1000VA UPS with standard power outlet. AC outlets quantity: 6 AC outlet(s) on the CyberPower OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA, 1 AC outlet(s) on the Trust Oxxtron 1000VA UPS with standard power outlet.

  • Output power capacity
    • OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA:1.5 kVA
    • Oxxtron 1000VA UPS with standard power outlet:1 kVA
  • Output power
    • OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA:900 W
    • Oxxtron 1000VA UPS with standard power outlet:560 W
  • Power protection features
    • OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA:Overload
    • Oxxtron 1000VA UPS with standard power outlet:Overload, Short circuit
  • AC outlets quantity
    • OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA:6 AC outlet(s)
    • Oxxtron 1000VA UPS with standard power outlet:1 AC outlet(s)
  • Form factor
    • OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA:Rackmount
    • Oxxtron 1000VA UPS with standard power outlet:Compact
  • Width
    • OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA:433 mm
    • Oxxtron 1000VA UPS with standard power outlet:95 mm
  • Depth
    • OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA:485 mm
    • Oxxtron 1000VA UPS with standard power outlet:320 mm
  • Height
    • OR1500ELCDRM1U uninterruptible power supply (UPS) 1.5 kVA:44 mm
    • Oxxtron 1000VA UPS with standard power outlet:160 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of OR1500ELCDRM1U, Oxxtron 1000VA UPS with standard power outlet
41 specifications
Features3 differ
Output power capacityDiffers1.5 kVA1 kVA
Output powerDiffers900 W560 W
Input operation voltage (min)Known for one160 VUnknown — not stated by the source
Input operation voltage (max)Known for one265 VUnknown — not stated by the source
Input frequencyKnown for one47/63 HzUnknown — not stated by the source
Output operation voltage (max)Known for one230 VUnknown — not stated by the source
Response timeKnown for one4 msUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionYesYes
Power protection featuresDiffersOverloadOverload, Short circuit
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneBattery replacementUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
Power plugKnown for oneC14 couplerUnknown — not stated by the source
AC outlets quantityDiffers6 AC outlet(s)1 AC outlet(s)
Number of output IEC jumpersKnown for one7Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one11 minUnknown — not stated by the source
Battery recharge timeKnown for one8 hUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmountCompact
Product colourBlackBlack
Rack capacityKnown for one1UUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for onePowerUnknown — not stated by the source
Certificatesidentical
CertificationKnown for one- RoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers433 mm95 mm
DepthDiffers485 mm320 mm
HeightDiffers44 mm160 mm
WeightDiffers19.4 kg6.91 kg
Packaging dataidentical
Bundled softwareKnown for one- PowerPanel Business EditionUnknown — not stated by the source
Other featuresidentical
Number of phasesKnown for one1Unknown — not stated by the source
Dimensions (WxDxH)Known for one433 x 485 x 44 mmUnknown — not stated by the source
Compatible operating systemsKnown for one- Windows Vista, XP, 7 - WindowsServer 2003, 2008, 2011 - LINUX - Mac x 10.4.1 +Unknown — not stated by the source
Mac compatibilityKnown for oneYesUnknown — not stated by the source
Over current protectionKnown for oneYesUnknown — not stated by the source
Overload protectionKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons