Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA vs Legrand TRIMOD HE 60kVA/kW 0min ARM.A

Add a product
  • 17specifications compared
  • 14differ
  • 3identical
  • 51known for one product only

Key differences

The Legrand TRIMOD HE 60kVA/kW 0min ARM.A has 59 kVA more output power capacity than the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA (60 kVA vs 1 kVA). The Legrand TRIMOD HE 60kVA/kW 0min ARM.A has 59,300 W more output power than the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA (60000 W vs 700 W). The Legrand TRIMOD HE 60kVA/kW 0min ARM.A has 302 V more input operation voltage (min) than the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA (380 V vs 78 V). UPS topology: Line-Interactive on the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA, Double-conversion (Online) on the Legrand TRIMOD HE 60kVA/kW 0min ARM.A. Input frequency: 50/60 Hz on the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA, 45/65 Hz on the Legrand TRIMOD HE 60kVA/kW 0min ARM.A.

  • UPS topology
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:Line-Interactive
    • TRIMOD HE 60kVA/kW 0min ARM.A:Double-conversion (Online)
  • Output power capacity
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:1 kVA
    • TRIMOD HE 60kVA/kW 0min ARM.A:60 kVA
  • Output power
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:700 W
    • TRIMOD HE 60kVA/kW 0min ARM.A:60000 W
  • Input operation voltage (min)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:78 V
    • TRIMOD HE 60kVA/kW 0min ARM.A:380 V
  • Input operation voltage (max)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:142 V
    • TRIMOD HE 60kVA/kW 0min ARM.A:415 V
  • Input frequency
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:50/60 Hz
    • TRIMOD HE 60kVA/kW 0min ARM.A:45/65 Hz
  • Output operation voltage (min)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:120 V
    • TRIMOD HE 60kVA/kW 0min ARM.A:380 V
  • Output operation voltage (max)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:120 V
    • TRIMOD HE 60kVA/kW 0min ARM.A:415 V

Side by side

Differences highlightedShow differences only (off)
Comparison of OR1000PFCLCD, TRIMOD HE 60kVA/kW 0min ARM.A
68 specifications
Features8 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1 kVA60 kVA
Output powerDiffers700 W60000 W
WaveformKnown for oneUnknown — not stated by the sourceSine
Input operation voltage (min)Differs78 V380 V
Input operation voltage (max)Differs142 V415 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (min)Differs120 V380 V
Output operation voltage (max)Differs120 V415 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Number of input phasesKnown for oneUnknown — not stated by the source3
Number of output phasesKnown for oneUnknown — not stated by the source3
EfficiencyKnown for oneUnknown — not stated by the source96%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source99%
Power factorKnown for oneUnknown — not stated by the source0.99
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Management protocolsKnown for oneUnknown — not stated by the sourceNetwork management,Simple Network Management Protocol (SNMP)
Power source typeKnown for oneUnknown — not stated by the sourceAC
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one1030 JUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Ports & interfacesidentical
RS-232 portsKnown for oneUnknown — not stated by the source2
AC outlet typesKnown for oneNEMA 5–15RUnknown — not stated by the source
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlets quantityKnown for one8 AC outlet(s)Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Batteryidentical
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Number of batteries supportedKnown for one1Unknown — not stated by the source
Typical backup time at full loadKnown for one2 minUnknown — not stated by the source
Typical backup time at half loadKnown for one10 minUnknown — not stated by the source
Battery recharge timeKnown for one8 hUnknown — not stated by the source
Design1 differ
Form factorDiffersMini TowerTower
Product colourBlackBlack
Display typeKnown for oneUnknown — not stated by the sourceLED
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP21
Cable lengthKnown for one1.8 mUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceEN 62040-1, EN 62040-2, EN 62040-3
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers137 mm414 mm
DepthDiffers163 mm628 mm
HeightDiffers351 mm1370 mm
WeightDiffers11.2 kg165 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source414 mm
Package depthKnown for oneUnknown — not stated by the source356.2 mm
Package heightKnown for oneUnknown — not stated by the source1370 mm
Package weightKnown for oneUnknown — not stated by the source178.9 kg
Logistics dataidentical
Products per palletKnown for oneUnknown — not stated by the source1 pc(s)
Pallet net heightKnown for oneUnknown — not stated by the source160 cm
Pallet net lengthKnown for oneUnknown — not stated by the source100 cm
Pallet net weightKnown for oneUnknown — not stated by the source188.3 kg
Pallet net widthKnown for oneUnknown — not stated by the source120 cm
Master (outer) case widthKnown for oneUnknown — not stated by the source800 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source1200 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source1610 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source188.3 kg
Products per master (outer) caseKnown for oneUnknown — not stated by the source1 pc(s)
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUL1778 4th, cUL 107.3-05, FCC/DoC Class BUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons