Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA vs Legrand Niky 1500VA 900W

Add a product
  • 21specifications compared
  • 16differ
  • 5identical
  • 22known for one product only

Key differences

The Legrand Niky 1500VA 900W has 0.5 kVA more output power capacity than the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA (1.5 kVA vs 1 kVA). The Legrand Niky 1500VA 900W has 200 W more output power than the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA (900 W vs 700 W). The Legrand Niky 1500VA 900W has 82 V more input operation voltage (min) than the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA (160 V vs 78 V). AC outlet types: NEMA 5–15R on the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA, C13 coupler on the Legrand Niky 1500VA 900W. AC outlets quantity: 8 AC outlet(s) on the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA, 6 AC outlet(s) on the Legrand Niky 1500VA 900W.

  • Output power capacity
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:1 kVA
    • Niky 1500VA 900W:1.5 kVA
  • Output power
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:700 W
    • Niky 1500VA 900W:900 W
  • Input operation voltage (min)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:78 V
    • Niky 1500VA 900W:160 V
  • Input operation voltage (max)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:142 V
    • Niky 1500VA 900W:290 V
  • Output operation voltage (min)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:120 V
    • Niky 1500VA 900W:207 V
  • Output operation voltage (max)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:120 V
    • Niky 1500VA 900W:253 V
  • AC outlet types
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:NEMA 5–15R
    • Niky 1500VA 900W:C13 coupler
  • AC outlets quantity
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:8 AC outlet(s)
    • Niky 1500VA 900W:6 AC outlet(s)

Side by side

Differences highlightedShow differences only (on)
Comparison of OR1000PFCLCD, Niky 1500VA 900W
43 specifications
Features6 differ
Output power capacityDiffers1 kVA1.5 kVA
Output powerDiffers700 W900 W
Input operation voltage (min)Differs78 V160 V
Input operation voltage (max)Differs142 V290 V
Output operation voltage (min)Differs120 V207 V
Output operation voltage (max)Differs120 V253 V
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one1030 JUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Noise levelKnown for oneUnknown — not stated by the source40 dB
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5–15RC13 coupler
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlets quantityDiffers8 AC outlet(s)6 AC outlet(s)
Battery3 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of batteries supportedDiffers12
Typical backup time at full loadDiffers2 min5 min
Typical backup time at half loadDiffers10 min30 min
Battery recharge timeKnown for one8 hUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Designidentical
Form factorKnown for oneMini TowerUnknown — not stated by the source
Cable lengthKnown for one1.8 mUnknown — not stated by the source
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditions1 differ
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceEN 62040-1, EN 62040-2, EN 62040-3
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUL1778 4th, cUL 107.3-05, FCC/DoC Class BUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers137 mm147 mm
DepthDiffers163 mm354 mm
HeightDiffers351 mm239 mm
WeightDiffers11.2 kg16 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.