Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA vs Legrand KEOR T10

Add a product
  • 15specifications compared
  • 13differ
  • 2identical
  • 35known for one product only

Key differences

The Legrand KEOR T10 has 9 kVA more output power capacity than the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA (10 kVA vs 1 kVA). The Legrand KEOR T10 has 8,300 W more output power than the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA (9000 W vs 700 W). The Legrand KEOR T10 has 130 V more input operation voltage (min) than the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA (208 V vs 78 V). UPS topology: Line-Interactive on the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA, Double-conversion (Online) on the Legrand KEOR T10. Input frequency: 50/60 Hz on the CyberPower OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA, 45/65 Hz on the Legrand KEOR T10.

  • UPS topology
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:Line-Interactive
    • KEOR T10:Double-conversion (Online)
  • Output power capacity
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:1 kVA
    • KEOR T10:10 kVA
  • Output power
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:700 W
    • KEOR T10:9000 W
  • Input operation voltage (min)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:78 V
    • KEOR T10:208 V
  • Input operation voltage (max)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:142 V
    • KEOR T10:467 V
  • Input frequency
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:50/60 Hz
    • KEOR T10:45/65 Hz
  • Output operation voltage (min)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:120 V
    • KEOR T10:380 V
  • Output operation voltage (max)
    • OR1000PFCLCD uninterruptible power supply (UPS) Line-Interactive 1 kVA:120 V
    • KEOR T10:415 V

Side by side

Differences highlightedShow differences only (off)
Comparison of OR1000PFCLCD, KEOR T10
50 specifications
Features8 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1 kVA10 kVA
Output powerDiffers700 W9000 W
Input operation voltage (min)Differs78 V208 V
Input operation voltage (max)Differs142 V467 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (min)Differs120 V380 V
Output operation voltage (max)Differs120 V415 V
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one1030 JUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
EfficiencyKnown for oneUnknown — not stated by the source96%
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source0.9
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Noise levelKnown for oneUnknown — not stated by the source55 dB
Ports & interfacesidentical
AC outlet typesKnown for oneNEMA 5–15RUnknown — not stated by the source
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlets quantityKnown for one8 AC outlet(s)Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of batteries supportedKnown for one1Unknown — not stated by the source
Typical backup time at full loadKnown for one2 minUnknown — not stated by the source
Typical backup time at half loadKnown for one10 minUnknown — not stated by the source
Battery recharge timeKnown for one8 hUnknown — not stated by the source
Designidentical
Form factorKnown for oneMini TowerUnknown — not stated by the source
Product colourBlackBlack
Cable lengthKnown for one1.8 mUnknown — not stated by the source
Display typeKnown for oneUnknown — not stated by the sourceLCD
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Differs0 - 90%20 - 95%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceEN 62040-1, EN 62040-2, EN 62040-3
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUL1778 4th, cUL 107.3-05, FCC/DoC Class BUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers137 mm400 mm
DepthDiffers163 mm800 mm
HeightDiffers351 mm1345 mm
WeightDiffers11.2 kg121 kg
Other featuresidentical
Number of phasesKnown for oneUnknown — not stated by the source3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.