Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OR1000EPFCRT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA vs CyberPower PR1000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 1 kVA

Add a product
  • 55specifications compared
  • 23differ
  • 32identical
  • 24known for one product only

Key differences

  • Output power
    • OR1000EPFCRT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:700 W
    • PR1000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:1000 W
  • Waveform
    • OR1000EPFCRT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:Sine
    • PR1000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:Pure sine
  • Input operation voltage (min)
    • OR1000EPFCRT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:160 V
    • PR1000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:159 V
  • Input operation voltage (max)
    • OR1000EPFCRT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:286 V
    • PR1000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:288 V
  • Surge energy rating
    • OR1000EPFCRT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:810 J
    • PR1000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:2430 J
  • Noise level
    • OR1000EPFCRT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:34.5 dB
    • PR1000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:57.5 dB
  • Power protection features
    • OR1000EPFCRT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:Short circuit
    • PR1000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:Overload
  • AC outlets quantity
    • OR1000EPFCRT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:8 AC outlet(s)
    • PR1000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:10 AC outlet(s)

Side by side

Differences highlightedShow differences only (off)
Comparison of OR1000EPFCRT2U, PR1000ERTXL2U
79 specifications
Features8 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacity1 kVA1 kVA
Output powerDiffers700 W1000 W
WaveformDiffersSinePure sine
Input operation voltage (min)Differs160 V159 V
Input operation voltage (max)Differs286 V288 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)220 V220 V
Output operation voltage (max)240 V240 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)YesYes
Maximum current10 A10 A
Surge energy ratingDiffers810 J2430 J
Response time4 ms4 ms
Heat dissipationKnown for oneUnknown — not stated by the source47.4 BTU/h
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Output power factorKnown for oneUnknown — not stated by the source1
Power Factor Correction (PFC) typeKnown for oneUnknown — not stated by the sourceActive
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
EMI/RFI noise filteringYesYes
Noise levelDiffers34.5 dB57.5 dB
Surge protectionYesYes
Power protection featuresDiffersShort circuitOverload
Audible alarm(s)YesYes
Audible alarm modesDiffersAlarm when on battery, Low battery alarm, Overload alarmAlarm when on battery, Fault, Low battery alarm, Overload alarm
Power factorKnown for one0.7Unknown — not stated by the source
Surge protection featuresKnown for oneDigital Subscriber Line (DSL), Fax, Modem, Network, TelephoneUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesC13 couplerC13 coupler
Power plugC14 couplerC14 coupler
AC outlets quantityDiffers8 AC outlet(s)10 AC outlet(s)
USB portYesYes
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial interfaceYesYes
Serial interface typeRS-232RS-232
RS-232 portsKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsDiffers12
Emergency Power Off (EPO) connectorYesYes
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Battery3 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Number of batteries supported11
Typical backup time at full loadDiffers8.4 min7.9 min
Typical backup time at half loadDiffers23.4 min21.3 min
Battery recharge timeDiffers6 h3 h
Hot-swap batteryYesYes
Design1 differ
Form factorRackmount/TowerRackmount/Tower
Product colourBlackBlack
Housing materialMetalMetal
Rack capacity2U2U
Cable lengthDiffers1.83 m3.05 m
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Built-in fanKnown for oneUnknown — not stated by the sourceYes
Control typeKnown for oneUnknown — not stated by the sourceButtons
Display typeLCDLCD
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Cables includedKnown for oneUnknown — not stated by the sourceSerial
ManualKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
Compliance certificatesDiffersRoHSCE, Federal Communications Commission (FCC), RCM, RoHS, UL, VCCI
CertificationKnown for oneCEUnknown — not stated by the source
Sustainabilityidentical
Sustainability complianceKnown for oneUnknown — not stated by the sourceYes
Weight & dimensions3 differ
Width433 mm433 mm
DepthDiffers388 mm412 mm
HeightDiffers88 mm86.5 mm
WeightDiffers22.1 kg30.4 kg
Packaging data4 differ
Package widthDiffers520 mm560 mm
Package depthDiffers542 mm530 mm
Package heightDiffers300 mm275 mm
Package weightDiffers24.5 kg30.2 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source8504408590
Country of originKnown for oneUnknown — not stated by the sourceChina
Other features1 differ
Battery typeDiffersRBP0109RBP0128

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.