Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OLS6000E uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA vs CyberPower PR750ELCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA

Add a product
  • 24specifications compared
  • 15differ
  • 9identical
  • 48known for one product only

Key differences

  • UPS topology
    • OLS6000E uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Double-conversion (Online)
    • PR750ELCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:Line-Interactive
  • Output power capacity
    • OLS6000E uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:6 kVA
    • PR750ELCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:0.75 kVA
  • Output power
    • OLS6000E uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:5400 W
    • PR750ELCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:500 W
  • Waveform
    • OLS6000E uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Pseudo sine
    • PR750ELCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:Sine
  • Input operation voltage (min)
    • OLS6000E uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:110 V
    • PR750ELCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:150 V
  • Input operation voltage (max)
    • OLS6000E uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:276 V
    • PR750ELCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:30 V
  • Input frequency
    • OLS6000E uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:50/60 Hz
    • PR750ELCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:47/63 Hz
  • AC outlet types
    • OLS6000E uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Terminal
    • PR750ELCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:C13 coupler

Side by side

Differences highlightedShow differences only (on)
Comparison of OLS6000E, PR750ELCDRT1U
72 specifications
Features7 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers6 kVA0.75 kVA
Output powerDiffers5400 W500 W
WaveformDiffersPseudo sineSine
Input operation voltage (min)Differs110 V150 V
Input operation voltage (max)Differs276 V30 V
Input frequencyDiffers50/60 Hz47/63 Hz
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Web-based managementKnown for oneUnknown — not stated by the sourceYes
Management protocolsKnown for oneUnknown — not stated by the sourceSNMP/HTTP
Auto-restartKnown for oneUnknown — not stated by the sourceYes
Surge energy ratingKnown for one445 JUnknown — not stated by the source
Efficiency (ECO mode)Known for one96%Unknown — not stated by the source
Power factorKnown for one0.9Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
ECO modeKnown for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Fault, Low battery alarm, Overload alarmUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersTerminalC13 coupler
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
AC outlets quantityKnown for oneUnknown — not stated by the source6 AC outlet(s)
Serial ports quantityKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
USB portKnown for oneYesUnknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Battery2 differ
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Battery capacityDiffers7 Ah9 Ah
Battery voltageDiffers12 V6 V
Number of batteries supportedKnown for oneUnknown — not stated by the source4
Typical backup time at full loadKnown for oneUnknown — not stated by the source7 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source23 min
Battery recharge timeKnown for oneUnknown — not stated by the source6 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Automatic battery testKnown for oneUnknown — not stated by the sourceYes
Battery weightKnown for one105 kgUnknown — not stated by the source
Design1 differ
Form factorDiffersTowerRackmount
Rack capacityKnown for oneUnknown — not stated by the source1U
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceUSB cable
ManualKnown for oneUnknown — not stated by the sourceYes
Weight & dimensions4 differ
WidthDiffers260 mm430 mm
DepthDiffers550 mm490 mm
HeightDiffers708 mm44 mm
WeightDiffers25 kg17.6 kg
Battery widthKnown for one26 cmUnknown — not stated by the source
Battery depthKnown for one55 cmUnknown — not stated by the source
Battery heightKnown for one71.8 cmUnknown — not stated by the source
Packaging dataidentical
BracketKnown for oneUnknown — not stated by the sourceYes
Resource CDKnown for oneUnknown — not stated by the sourceYes
Bundled softwareKnown for oneUnknown — not stated by the sourcePowerPanel Business Edition
Package widthKnown for one428 mmUnknown — not stated by the source
Package depthKnown for one720 mmUnknown — not stated by the source
Package heightKnown for one970 mmUnknown — not stated by the source
Package weightKnown for one37 kgUnknown — not stated by the source
Other featuresidentical
Output voltageKnown for oneUnknown — not stated by the source230 V
PurposeKnown for one3D PrinterUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.