Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OLS5KERT4UA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA vs CyberPower PR3000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA

Add a product
  • 64specifications compared
  • 27differ
  • 37identical
  • 28known for one product only

Key differences

  • UPS topology
    • OLS5KERT4UA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:Double-conversion (Online)
    • PR3000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA:Line-Interactive
  • Output power capacity
    • OLS5KERT4UA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:5 kVA
    • PR3000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA:3 kVA
  • Output power
    • OLS5KERT4UA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:4800 W
    • PR3000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA:3000 W
  • Input operation voltage (min)
    • OLS5KERT4UA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:110 V
    • PR3000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA:148 V
  • Input operation voltage (max)
    • OLS5KERT4UA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:300 V
    • PR3000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA:288 V
  • Output operation voltage (min)
    • OLS5KERT4UA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:200 V
    • PR3000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA:220 V
  • Maximum current
    • OLS5KERT4UA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:25 A
    • PR3000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA:16 A
  • Surge energy rating
    • OLS5KERT4UA-IEC uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:1335 J
    • PR3000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 3 kVA:2430 J

Side by side

Differences highlightedShow differences only (on)
Comparison of OLS5KERT4UA-IEC, PR3000ERTXL2UC
92 specifications
Features10 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers5 kVA3 kVA
Output powerDiffers4800 W3000 W
Input operation voltage (min)Differs110 V148 V
Input operation voltage (max)Differs300 V288 V
Output operation voltage (min)Differs200 V220 V
Output frequency regulationKnown for one0.5 HzUnknown — not stated by the source
Output voltage regulationKnown for one1%Unknown — not stated by the source
Maximum currentDiffers25 A16 A
Surge energy ratingDiffers1335 J2430 J
Heat dissipationDiffers1777 BTU/h192.5 BTU/h
Efficiency (ECO mode)Known for one98%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Output power factorDiffers0.961
Crest factorKnown for one3:1Unknown — not stated by the source
ECO modeKnown for oneYesUnknown — not stated by the source
Total Harmonic Distortion (THD) (linear load)Known for one1.5%Unknown — not stated by the source
Total Harmonic Distortion (THD) (non-linear load)Known for one2%Unknown — not stated by the source
Socket circuit breakerKnown for oneYesUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Response timeKnown for oneUnknown — not stated by the source6 ms
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Fault, Low battery alarm, Overload alarm
Ports & interfaces5 differ
AC outlet typesDiffersC13 coupler, C19 coupler, TerminalC13 coupler, C19 coupler
Power plugDiffersTerminalC20 coupler
AC outlets quantityDiffers15 AC outlet(s)8 AC outlet(s)
RS-232 portsDiffers32
Serial ports quantityDiffers32
SmartSlotKnown for oneYesUnknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Battery3 differ
Typical backup time at full loadDiffers8 min1.7 min
Typical backup time at half loadDiffers18 min7.1 min
Battery recharge timeDiffers4 h3 h
Charging currentKnown for one4 AUnknown — not stated by the source
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Design1 differ
Rack capacityDiffers4U2U
Extended battery module rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthKnown for oneUnknown — not stated by the source3.05 m
Certificates1 differ
Compliance certificatesDiffersCE, RoHSCE, Federal Communications Commission (FCC), RCM, RoHS, UL, VCCI
Weight & dimensions3 differ
DepthDiffers661 mm500 mm
HeightDiffers171 mm86.5 mm
WeightDiffers63 kg32.8 kg
Packaging data4 differ
Package widthDiffers575 mm560 mm
Package depthDiffers890 mm620 mm
Package heightDiffers404 mm275 mm
Package weightDiffers81 kg40.8 kg
Other featuresidentical
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Overload protectionKnown for oneYesUnknown — not stated by the source
Quantity of delay expansion units (max)Known for one4Unknown — not stated by the source
Battery typeKnown for oneUnknown — not stated by the sourceRBP0128
Packaging contentidentical
Batteries includedKnown for oneUnknown — not stated by the sourceYes
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Cables includedKnown for oneUnknown — not stated by the sourceSerial
ManualKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.