Product comparison · 2 uninterruptible power supplies (upss)

CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA vs Salicru SLC 10000 TWIN PRO3 DUAL B1

Add a product
  • 24specifications compared
  • 13differ
  • 11identical
  • 45known for one product only

Key differences

The Salicru SLC 10000 TWIN PRO3 DUAL B1 has 7 kVA more output power capacity than the CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA (10 kVA vs 3 kVA). The Salicru SLC 10000 TWIN PRO3 DUAL B1 has 7,000 W more output power than the CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA (10000 W vs 3000 W). The CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 24 V more input operation voltage (max) than the Salicru SLC 10000 TWIN PRO3 DUAL B1 (300 V vs 276 V). Input frequency: 50/60 Hz on the CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA, 40 - 70 Hz on the Salicru SLC 10000 TWIN PRO3 DUAL B1. Power protection features: Overload on the CyberPower Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA, Over voltage, Under voltage, Overheating on the Salicru SLC 10000 TWIN PRO3 DUAL B1.

  • Output power capacity
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • SLC 10000 TWIN PRO3 DUAL B1:10 kVA
  • Output power
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3000 W
    • SLC 10000 TWIN PRO3 DUAL B1:10000 W
  • Input operation voltage (max)
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:300 V
    • SLC 10000 TWIN PRO3 DUAL B1:276 V
  • Input frequency
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:50/60 Hz
    • SLC 10000 TWIN PRO3 DUAL B1:40 - 70 Hz
  • Number of input phases
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:1
    • SLC 10000 TWIN PRO3 DUAL B1:3
  • Charging current
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:8 A
    • SLC 10000 TWIN PRO3 DUAL B1:12 A
  • Form factor
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Rackmount/Tower
    • SLC 10000 TWIN PRO3 DUAL B1:Tower
  • Operating relative humidity (H-H)
    • Online S Series OLS3KERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:20 - 90%
    • SLC 10000 TWIN PRO3 DUAL B1:0 - 95%

Side by side

Differences highlightedShow differences only (on)
Comparison of OLS3KERT2UH, SLC 10000 TWIN PRO3 DUAL B1
69 specifications
Features6 differ
Output power capacityDiffers3 kVA10 kVA
Output powerDiffers3000 W10000 W
WaveformKnown for onePure sineUnknown — not stated by the source
Input operation voltage (max)Differs300 V276 V
Input frequencyDiffers50/60 Hz40 - 70 Hz
Output operation voltage (min)Known for one200 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentKnown for one14.02 AUnknown — not stated by the source
Surge energy ratingKnown for one1065 JUnknown — not stated by the source
Heat dissipationKnown for one653 BTU/hUnknown — not stated by the source
Number of input phasesDiffers13
Efficiency (ECO mode)Known for one98%Unknown — not stated by the source
Power factorKnown for one1Unknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresDiffersOverloadOver voltage, Under voltage, Overheating
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Battery replacement, Fault, Low battery alarm, Overload alarmUnknown — not stated by the source
Number of output phasesKnown for oneUnknown — not stated by the source1
Noise levelKnown for oneUnknown — not stated by the source60 dB
Maximum number of paralleling UPSsKnown for oneUnknown — not stated by the source3
Ports & interfacesidentical
AC outlet typesKnown for oneC13 coupler, C19 couplerUnknown — not stated by the source
AC outlets quantityKnown for one7 AC outlet(s)Unknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-B
Parallel ports quantityKnown for oneUnknown — not stated by the source1
HDMI ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
SmartSlotKnown for oneUnknown — not stated by the sourceYes
Battery1 differ
Battery voltageKnown for one72 VUnknown — not stated by the source
Typical backup time at full loadKnown for one2.5 minUnknown — not stated by the source
Typical backup time at half loadKnown for one9.5 minUnknown — not stated by the source
Battery recharge timeKnown for one4 hUnknown — not stated by the source
Charging currentDiffers8 A12 A
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Replacement battery cartridgeKnown for oneRBP0160Unknown — not stated by the source
Battery technologyKnown for oneUnknown — not stated by the sourceLead-Calcium (Pb-Ca)
Cold startKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorDiffersRackmount/TowerTower
Housing materialKnown for oneMetalUnknown — not stated by the source
Cable lengthKnown for one1.5 mUnknown — not stated by the source
Control typeKnown for oneButtonsUnknown — not stated by the source
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Built-in fanKnown for oneUnknown — not stated by the sourceYes
Operational conditions2 differ
Storage temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Operating relative humidity (H-H)Differs20 - 90%0 - 95%
Storage relative humidity (H-H)Known for one10 - 90%Unknown — not stated by the source
Operating altitudeDiffers0 - 1500 m0 - 30000 m
Non-operating altitudeKnown for one0 - 1500 mUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneCE, RCM RoHSUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers540 mm225 mm
DepthDiffers730 mm492 mm
HeightDiffers230 mm589 mm
WeightKnown for oneUnknown — not stated by the source59.5 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.