Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA vs CyberPower PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA

Add a product
  • 27specifications compared
  • 18differ
  • 9identical
  • 31known for one product only

Key differences

The CyberPower PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA has 4.5 kVA more output power capacity than the CyberPower OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA (7.5 kVA vs 3 kVA). The CyberPower OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 2,025 W more output power than the CyberPower PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA (2700 W vs 675 W). The CyberPower PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA has 60 V more input operation voltage (min) than the CyberPower OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA (150 V vs 90 V). UPS topology: Double-conversion (Online) on the CyberPower OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA, Line-Interactive on the CyberPower PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA. AC outlet types: NEMA L5-20R on the CyberPower OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA, C14 coupler on the CyberPower PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA.

  • UPS topology
    • OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Double-conversion (Online)
    • PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA:Line-Interactive
  • Output power capacity
    • OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA:7.5 kVA
  • Output power
    • OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2700 W
    • PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA:675 W
  • Input operation voltage (min)
    • OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:90 V
    • PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA:150 V
  • Input operation voltage (max)
    • OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:150 V
    • PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA:301 V
  • Output operation voltage (min)
    • OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:100 V
    • PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA:230 V
  • Output operation voltage (max)
    • OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:127 V
    • PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA:230 V
  • Power factor
    • OLS3000RT2UA uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:0.99
    • PR750ELCDN uninterruptible power supply (UPS) Line-Interactive 7.5 kVA:0.9

Side by side

Differences highlightedShow differences only (on)
Comparison of OLS3000RT2UA, PR750ELCDN
58 specifications
Features8 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers3 kVA7.5 kVA
Output powerDiffers2700 W675 W
Input operation voltage (min)Differs90 V150 V
Input operation voltage (max)Differs150 V301 V
Output operation voltage (min)Differs100 V230 V
Output operation voltage (max)Differs127 V230 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Maximum currentKnown for oneUnknown — not stated by the source10 A
Surge energy ratingKnown for oneUnknown — not stated by the source405 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Power factorDiffers0.990.9
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Fault, Low battery alarm, Overload alarm
ECO modeKnown for oneYesUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersNEMA L5-20RC14 coupler
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
USB portKnown for oneUnknown — not stated by the sourceYes
Battery1 differ
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Typical backup time at full loadKnown for oneUnknown — not stated by the source2.5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source10.5 min
Battery recharge timeDiffers4 h8 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Battery voltageKnown for one72 VUnknown — not stated by the source
Design1 differ
Cable lengthDiffers1.5 m1.8 m
LED indicatorsKnown for oneUnknown — not stated by the sourceError, Operation
Rack capacityKnown for one2UUnknown — not stated by the source
Operational conditions3 differ
Storage temperature (T-T)Differs-20 - 50 °C-15 - 45 °C
Operating relative humidity (H-H)Differs20 - 90%0 - 95%
Storage relative humidity (H-H)Differs10 - 90%0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceSerial, USB cable
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
CertificationKnown for oneUnknown — not stated by the sourceCE, EAC, RCM
Weight & dimensions4 differ
WidthDiffers438 mm136 mm
DepthDiffers610 mm349 mm
HeightDiffers88 mm162 mm
WeightDiffers28.5 kg12.3 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source272 mm
Package depthKnown for oneUnknown — not stated by the source486 mm
Package heightKnown for oneUnknown — not stated by the source283 mm
Package weightKnown for oneUnknown — not stated by the source13.3 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source8504408590
Country of originKnown for oneUnknown — not stated by the sourceChina

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.