Key differences

The Salicru SLC 10000 TWIN PRO3 DUAL B1 has 7 kVA more output power capacity than the CyberPower LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA (10 kVA vs 3 kVA). The Salicru SLC 10000 TWIN PRO3 DUAL B1 has 7,300 W more output power than the CyberPower LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA (10000 W vs 2700 W). The CyberPower LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 80 V more input operation voltage (min) than the Salicru SLC 10000 TWIN PRO3 DUAL B1 (190 V vs 110 V). Input frequency: 50/60 Hz on the CyberPower LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA, 40 - 70 Hz on the Salicru SLC 10000 TWIN PRO3 DUAL B1. Power protection features: Overload on the CyberPower LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA, Over voltage, Under voltage, Overheating on the Salicru SLC 10000 TWIN PRO3 DUAL B1.

  • Output power capacity
    • LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • SLC 10000 TWIN PRO3 DUAL B1:10 kVA
  • Output power
    • LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2700 W
    • SLC 10000 TWIN PRO3 DUAL B1:10000 W
  • Input operation voltage (min)
    • LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:190 V
    • SLC 10000 TWIN PRO3 DUAL B1:110 V
  • Input operation voltage (max)
    • LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:300 V
    • SLC 10000 TWIN PRO3 DUAL B1:276 V
  • Input frequency
    • LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:50/60 Hz
    • SLC 10000 TWIN PRO3 DUAL B1:40 - 70 Hz
  • Number of input phases
    • LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:1
    • SLC 10000 TWIN PRO3 DUAL B1:3
  • Battery technology
    • LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Sealed Lead Acid (VRLA)
    • SLC 10000 TWIN PRO3 DUAL B1:Lead-Calcium (Pb-Ca)
  • Charging current
    • LCD OLS3000ERT2UA-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:1.5 A
    • SLC 10000 TWIN PRO3 DUAL B1:12 A

Side by side

Differences highlightedShow differences only (off)
Comparison of OLS3000ERT2UA-B, SLC 10000 TWIN PRO3 DUAL B1
86 specifications
Features7 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers3 kVA10 kVA
Output powerDiffers2700 W10000 W
WaveformKnown for onePure sineUnknown — not stated by the source
Input operation voltage (min)Differs190 V110 V
Input operation voltage (max)Differs300 V276 V
Input frequencyDiffers50/60 Hz40 - 70 Hz
Output operation voltage (min)Known for one208 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Output frequency regulationKnown for one0.5 HzUnknown — not stated by the source
Output voltage regulationKnown for one1%Unknown — not stated by the source
Maximum currentKnown for one13 AUnknown — not stated by the source
Surge energy ratingKnown for one388 JUnknown — not stated by the source
Response timeKnown for one0 msUnknown — not stated by the source
Heat dissipationKnown for one911 BTU/hUnknown — not stated by the source
Number of input phasesDiffers13
Number of output phases11
Efficiency (ECO mode)Known for one95%Unknown — not stated by the source
Input power factor0.990.99
Output power factorKnown for one0.9Unknown — not stated by the source
ECO modeYesYes
Emergency Power Off (EPO)YesYes
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresDiffersOverloadOver voltage, Under voltage, Overheating
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneBattery replacement, Low battery alarm, Overload alarm, Fault, Alarm when on batteryUnknown — not stated by the source
Noise levelKnown for oneUnknown — not stated by the source60 dB
Maximum number of paralleling UPSsKnown for oneUnknown — not stated by the source3
Ports & interfacesidentical
AC outlet typesKnown for oneC13 coupler, C19 couplerUnknown — not stated by the source
Power plugKnown for oneType FUnknown — not stated by the source
AC outlets quantityKnown for one10 AC outlet(s)Unknown — not stated by the source
USB portYesYes
USB port typeUSB Type-BUSB Type-B
Serial interfaceYesYes
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) ports11
Emergency Power Off (EPO) connectorYesYes
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Parallel ports quantityKnown for oneUnknown — not stated by the source1
HDMI ports quantityKnown for oneUnknown — not stated by the source1
SmartSlotKnown for oneUnknown — not stated by the sourceYes
Battery2 differ
Battery technologyDiffersSealed Lead Acid (VRLA)Lead-Calcium (Pb-Ca)
Battery voltageKnown for one72 VUnknown — not stated by the source
Number of batteries includedKnown for one2 pc(s)Unknown — not stated by the source
Number of batteries supportedKnown for one3Unknown — not stated by the source
Typical backup time at full loadKnown for one4.2 minUnknown — not stated by the source
Typical backup time at half loadKnown for one13.1 minUnknown — not stated by the source
Battery recharge timeKnown for one4 hUnknown — not stated by the source
Charging currentDiffers1.5 A12 A
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Replacement battery cartridgeKnown for oneRBP0158Unknown — not stated by the source
Cold startKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorDiffersRackmount/TowerTower
Product colourBlackBlack
Housing materialKnown for oneMetalUnknown — not stated by the source
Rack capacityKnown for one2UUnknown — not stated by the source
Cable lengthKnown for one1.5 mUnknown — not stated by the source
Cooling typeActiveActive
Built-in fanYesYes
Control typeKnown for oneButtonsUnknown — not stated by the source
Display typeLCDLCD
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Known for one-20 - 50%Unknown — not stated by the source
Operating altitudeDiffers0 - 1500 m0 - 30000 m
Packaging contentidentical
Batteries includedKnown for oneYesUnknown — not stated by the source
Rack mount kitKnown for oneYesUnknown — not stated by the source
Cables includedKnown for oneInput power cable, USB cableUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCE, EAC, RoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers438 mm225 mm
DepthDiffers610 mm492 mm
HeightDiffers88 mm589 mm
WeightDiffers26.7 kg59.5 kg
Packaging dataidentical
Package widthKnown for one540 mmUnknown — not stated by the source
Package depthKnown for one730 mmUnknown — not stated by the source
Package heightKnown for one230 mmUnknown — not stated by the source
Package weightKnown for one30.8 kgUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneChinaUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.