Product comparison · 2 uninterruptible power supplies (upss)

CyberPower Online S Series Online Double Conversion USV 2000VA/1800WTower, ECO Mode, LCD, USB, Smart-Slot vs CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA

Add a product
  • 35specifications compared
  • 22differ
  • 13identical
  • 41known for one product only

Key differences

  • UPS topology
    • Online S Series Online Double Conversion USV 2000VA/1800WTower, ECO Mode, LCD, USB, Smart-Slot:Double-conversion (Online)
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:Line-Interactive
  • Output power
    • Online S Series Online Double Conversion USV 2000VA/1800WTower, ECO Mode, LCD, USB, Smart-Slot:1800 W
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:2000 W
  • Input operation voltage (min)
    • Online S Series Online Double Conversion USV 2000VA/1800WTower, ECO Mode, LCD, USB, Smart-Slot:80 V
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:131 V
  • Input operation voltage (max)
    • Online S Series Online Double Conversion USV 2000VA/1800WTower, ECO Mode, LCD, USB, Smart-Slot:300 V
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:302 V
  • Output operation voltage (min)
    • Online S Series Online Double Conversion USV 2000VA/1800WTower, ECO Mode, LCD, USB, Smart-Slot:208 V
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:200 V
  • AC outlet types
    • Online S Series Online Double Conversion USV 2000VA/1800WTower, ECO Mode, LCD, USB, Smart-Slot:C13 coupler, Type F
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:C13 coupler
  • Power plug
    • Online S Series Online Double Conversion USV 2000VA/1800WTower, ECO Mode, LCD, USB, Smart-Slot:Type F
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:C14 coupler
  • AC outlets quantity
    • Online S Series Online Double Conversion USV 2000VA/1800WTower, ECO Mode, LCD, USB, Smart-Slot:4 AC outlet(s)
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:10 AC outlet(s)

Side by side

Differences highlightedShow differences only (off)
Comparison of OLS2KECR, PR2000ERTXL2UC
76 specifications
Features6 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacity2 kVA2 kVA
Output powerDiffers1800 W2000 W
WaveformPure sinePure sine
Input operation voltage (min)Differs80 V131 V
Input operation voltage (max)Differs300 V302 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)Differs208 V200 V
Output operation voltage (max)240 V240 V
Output frequency50/60 Hz50/60 Hz
Output voltage regulationKnown for one1%Unknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for one9 AUnknown — not stated by the source
Surge energy ratingKnown for one440 JUnknown — not stated by the source
Heat dissipationKnown for one607 BTU/hUnknown — not stated by the source
Efficiency (ECO mode)Known for one96%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Output power factorKnown for one0.9Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
ECO modeKnown for oneYesUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Overload capacity (1 minute)Known for one120%Unknown — not stated by the source
Overload capacity (10 seconds)Known for one120%Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresDiffersInput fuse, OverloadOvercharge, Overload, Surge protection
Audible alarm(s)YesYes
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarm, Overload alarm, Fault, Battery replacementUnknown — not stated by the source
Socket circuit breakerKnown for oneYesUnknown — not stated by the source
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Noise levelKnown for oneUnknown — not stated by the source38.5 dB
Ports & interfaces3 differ
AC outlet typesDiffersC13 coupler, Type FC13 coupler
Power plugDiffersType FC14 coupler
AC outlets quantityDiffers4 AC outlet(s)10 AC outlet(s)
USB portYesYes
USB port typeKnown for oneUSB Type-BUnknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
Battery5 differ
Battery replacement accessibilityKnown for oneProfessional onlyUnknown — not stated by the source
Battery technologyDiffersSealed Lead Acid (VRLA)Lead-Acid
Battery capacityKnown for one9 AhUnknown — not stated by the source
Battery voltageKnown for one12 VUnknown — not stated by the source
Number of batteries supportedKnown for one4Unknown — not stated by the source
Typical backup time at full loadDiffers3 min4 min
Typical backup time at half loadDiffers14.3 min12 min
Battery recharge timeDiffers4 h3 h
Charging currentKnown for one1.5 AUnknown — not stated by the source
Replacement battery cartridgeDiffersBPS48V40ACRBP0129
Design1 differ
Form factorDiffersTowerRackmount/Tower
Product colourBlackBlack
Housing materialMetalMetal
Cable lengthKnown for one1.5 mUnknown — not stated by the source
Display typeLCDLCD
LED indicatorsKnown for oneUnknown — not stated by the sourcePower, Fault
Operational conditions2 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-20 - 50 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeDiffers0 - 1500 m0 - 3000 m
Non-operating altitudeKnown for one0 - 1500 mUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneUSB cableUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersCE, EAC, UKCA, RoHSCE, Federal Communications Commission (FCC), cUL, UL, VCCI, RoHS
Weight & dimensions4 differ
WidthDiffers110 mm433 mm
DepthDiffers390 mm500 mm
HeightDiffers345 mm86.5 mm
WeightDiffers17 kg3.44 kg
Other featuresidentical
BypassKnown for oneGreenPower UPSUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source560 mm
Package depthKnown for oneUnknown — not stated by the source620 mm
Package heightKnown for oneUnknown — not stated by the source275 mm
Package weightKnown for oneUnknown — not stated by the source4.13 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.