Product comparison · 2 uninterruptible power supplies (upss)

CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA vs Salicru SLC-10000-TWIN PRO3 MULTI

Add a product
  • 31specifications compared
  • 16differ
  • 15identical
  • 41known for one product only

Key differences

The Salicru SLC-10000-TWIN PRO3 MULTI has 7.8 kVA more output power capacity than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (10 kVA vs 2.2 kVA). The Salicru SLC-10000-TWIN PRO3 MULTI has 7,800 W more output power than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (10000 W vs 2200 W). The Salicru SLC-10000-TWIN PRO3 MULTI has 20 V more output operation voltage (min) than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (220 V vs 200 V). Input frequency: 50/60 Hz on the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA, 40 - 70 Hz on the Salicru SLC-10000-TWIN PRO3 MULTI. AC outlet types: C13 coupler on the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA, Type F on the Salicru SLC-10000-TWIN PRO3 MULTI.

  • Output power capacity
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2.2 kVA
    • SLC-10000-TWIN PRO3 MULTI:10 kVA
  • Output power
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2200 W
    • SLC-10000-TWIN PRO3 MULTI:10000 W
  • Input frequency
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:50/60 Hz
    • SLC-10000-TWIN PRO3 MULTI:40 - 70 Hz
  • Output operation voltage (min)
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:200 V
    • SLC-10000-TWIN PRO3 MULTI:220 V
  • Number of input phases
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:1
    • SLC-10000-TWIN PRO3 MULTI:3
  • AC outlet types
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:C13 coupler
    • SLC-10000-TWIN PRO3 MULTI:Type F
  • AC outlets quantity
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:6 AC outlet(s)
    • SLC-10000-TWIN PRO3 MULTI:1 AC outlet(s)
  • Battery recharge time
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:4 h
    • SLC-10000-TWIN PRO3 MULTI:3 h

Side by side

Differences highlightedShow differences only (on)
Comparison of OLS2K2ERT2UH, SLC-10000-TWIN PRO3 MULTI
72 specifications
Features6 differ
Output power capacityDiffers2.2 kVA10 kVA
Output powerDiffers2200 W10000 W
WaveformKnown for onePure sineUnknown — not stated by the source
Input frequencyDiffers50/60 Hz40 - 70 Hz
Output operation voltage (min)Differs200 V220 V
Maximum currentKnown for one10.39 AUnknown — not stated by the source
Surge energy ratingKnown for one1065 JUnknown — not stated by the source
Heat dissipationKnown for one564 BTU/hUnknown — not stated by the source
Number of input phasesDiffers13
Power factorKnown for one1Unknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresDiffersOverloadOver voltage, Under total voltage, Overheating
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarm, Overload alarm, Battery replacement, FaultUnknown — not stated by the source
Output voltage regulationKnown for oneUnknown — not stated by the source1%
Number of output phasesKnown for oneUnknown — not stated by the source3
Efficiency (On-line mode)Known for oneUnknown — not stated by the source95%
Output power factorKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Noise levelKnown for oneUnknown — not stated by the source60 dB
Maximum number of paralleling UPSsKnown for oneUnknown — not stated by the source3
Temperature voltage compensationKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersC13 couplerType F
AC outlets quantityDiffers6 AC outlet(s)1 AC outlet(s)
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-B
Parallel ports quantityKnown for oneUnknown — not stated by the source1
HDMI ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
SmartSlotKnown for oneUnknown — not stated by the sourceYes
Battery2 differ
Battery voltageKnown for one72 VUnknown — not stated by the source
Typical backup time at full loadKnown for one4 minUnknown — not stated by the source
Typical backup time at half loadKnown for one12 minUnknown — not stated by the source
Battery recharge timeDiffers4 h3 h
Charging currentDiffers8 A13 A
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Replacement battery cartridgeKnown for oneRBP0161Unknown — not stated by the source
Battery technologyKnown for oneUnknown — not stated by the sourceLead-Calcium (Pb-Ca)
Number of batteries supportedKnown for oneUnknown — not stated by the source3
Cold startKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorDiffersRackmount/TowerTower
Housing materialKnown for oneMetalUnknown — not stated by the source
Cable lengthKnown for one1.5 mUnknown — not stated by the source
Control typeKnown for oneButtonsUnknown — not stated by the source
Operational conditions2 differ
Storage temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Operating relative humidity (H-H)Differs20 - 90%0 - 95%
Storage relative humidity (H-H)Known for one10 - 90%Unknown — not stated by the source
Operating altitudeDiffers0 - 1500 m0 - 4000 m
Non-operating altitudeKnown for one0 - 1500 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers540 mm300 mm
DepthDiffers730 mm699 mm
HeightDiffers230 mm805 mm
WeightKnown for oneUnknown — not stated by the source69 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons