Product comparison · 2 uninterruptible power supplies (upss)

CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA vs Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA

Add a product
  • 22specifications compared
  • 13differ
  • 9identical
  • 43known for one product only

Key differences

The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 0.8 kVA more output power capacity than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (3 kVA vs 2.2 kVA). The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 800 W more output power than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (3000 W vs 2200 W). The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 110 V more input operation voltage (min) than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (220 V vs 110 V). Waveform: Pure sine on the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA, Sine on the Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA. AC outlet types: C13 coupler on the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA, C19 coupler, C13 coupler on the Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA.

  • Output power capacity
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2.2 kVA
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
  • Output power
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2200 W
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3000 W
  • Waveform
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:Pure sine
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Sine
  • Input operation voltage (min)
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:110 V
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:220 V
  • Input operation voltage (max)
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:300 V
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
  • Efficiency (ECO mode)
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:98%
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:98.3%
  • AC outlet types
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:C13 coupler
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:C19 coupler, C13 coupler
  • AC outlets quantity
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:6 AC outlet(s)
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:7 AC outlet(s)

Side by side

Differences highlightedShow differences only (off)
Comparison of OLS2K2ERT2UH, Keor-DK-3000-B
65 specifications
Features6 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers2.2 kVA3 kVA
Output powerDiffers2200 W3000 W
WaveformDiffersPure sineSine
Input operation voltage (min)Differs110 V220 V
Input operation voltage (max)Differs300 V240 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)Known for one200 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Maximum currentKnown for one10.39 AUnknown — not stated by the source
Surge energy ratingKnown for one1065 JUnknown — not stated by the source
Heat dissipationKnown for one564 BTU/hUnknown — not stated by the source
Number of input phasesKnown for one1Unknown — not stated by the source
Efficiency (ECO mode)Differs98%98.3%
Power factor11
Input power factorKnown for one0.99Unknown — not stated by the source
ECO modeYesYes
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionYesYes
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarm, Overload alarm, Battery replacement, FaultUnknown — not stated by the source
EfficiencyKnown for oneUnknown — not stated by the source98%
Efficiency (On-line mode)Known for oneUnknown — not stated by the source96%
Output power factorKnown for oneUnknown — not stated by the source1
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesDiffersC13 couplerC19 coupler, C13 coupler
AC outlets quantityDiffers6 AC outlet(s)7 AC outlet(s)
USB portYesYes
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Network card slotKnown for oneUnknown — not stated by the sourceYes
Battery1 differ
Battery voltageDiffers72 V12 V
Typical backup time at full loadKnown for one4 minUnknown — not stated by the source
Typical backup time at half loadKnown for one12 minUnknown — not stated by the source
Battery recharge time4 h4 h
Charging currentKnown for one8 AUnknown — not stated by the source
Hot-swap batteryYesYes
Replacement battery cartridgeKnown for oneRBP0161Unknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Number of batteries includedKnown for oneUnknown — not stated by the source6 pc(s)
Number of battery cellsKnown for oneUnknown — not stated by the source6
Design1 differ
Form factorRackmount/TowerRackmount/Tower
Product colourDiffersBlackBlack, White
Housing materialKnown for oneMetalUnknown — not stated by the source
Cable lengthKnown for one1.5 mUnknown — not stated by the source
Control typeKnown for oneButtonsUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
Rack capacityKnown for oneUnknown — not stated by the source2U
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one20 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one10 - 90%Unknown — not stated by the source
Operating altitudeKnown for one0 - 1500 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 1500 mUnknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers540 mm440 mm
DepthDiffers730 mm640 mm
HeightDiffers230 mm88 mm
WeightKnown for oneUnknown — not stated by the source2.7 kg
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Quick installation guideKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.