Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA vs CyberPower OLS1500ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA

Add a product
  • 44specifications compared
  • 6differ
  • 38identical
  • 0known for one product only

Key differences

  • Output power capacity
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:1 kVA
    • OLS1500ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:1.5 kVA
  • Output power
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:800 W
    • OLS1500ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:1200 W
  • Battery capacity
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:7 Ah
    • OLS1500ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:8.5 Ah
  • Typical backup time at full load
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:6 min
    • OLS1500ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:5 min
  • Typical backup time at half load
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:16 min
    • OLS1500ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:14 min
  • Weight
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:13.2 kg
    • OLS1500ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:14.6 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of OLS1000ERT2U, OLS1500ERT2U
44 specifications
Features2 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers1 kVA1.5 kVA
Output powerDiffers800 W1200 W
WaveformSineSine
Input frequency40/70 Hz40/70 Hz
Output operation voltage (min)208 V208 V
Output operation voltage (max)240 V240 V
Efficiency95%95%
Emergency Power Off (EPO)YesYes
Output voltage Total Harmonic Distortion (THD)3%3%
EMI/RFI noise filteringYesYes
Surge protectionYesYes
Surge protection featuresFax, Modem, Network, TelephoneFax, Modem, Network, Telephone
Power protection featuresOverloadOverload
Audible alarm(s)YesYes
Audible alarm modesBattery replacementBattery replacement
Auto-restartYesYes
Ports & interfacesidentical
AC outlet typesC13 couplerC13 coupler
Power plugC14 couplerC14 coupler
AC outlets quantity6 AC outlet(s)6 AC outlet(s)
USB 2.0 ports quantity11
Serial ports quantity11
Modem (RJ-11) ports22
Ethernet LAN (RJ-45) ports22
Battery3 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacityDiffers7 Ah8.5 Ah
Battery voltage12 V12 V
Number of batteries supported33
Typical backup time at full loadDiffers6 min5 min
Typical backup time at half loadDiffers16 min14 min
Battery recharge time5 h5 h
Automatic battery testYesYes
Cold startYesYes
Designidentical
Form factorRackmount/TowerRackmount/Tower
Product colourBlackBlack
Rack capacity2U2U
Cooling typeActiveActive
Display typeLCDLCD
LED indicatorsBattery replacementBattery replacement
Weight & dimensions1 differ
Width438 mm438 mm
Depth430 mm430 mm
Height88 mm88 mm
WeightDiffers13.2 kg14.6 kg
Packaging dataidentical
Bundled softwarePowerPanel Business EdPowerPanel Business Ed

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.