Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA vs CyberPower UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA

Add a product
  • 32specifications compared
  • 20differ
  • 12identical
  • 39known for one product only

Key differences

  • UPS topology
    • OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:Double-conversion (Online)
    • UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Line-Interactive
  • Output power capacity
    • OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:1 kVA
    • UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
  • Input operation voltage (min)
    • OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:80 V
    • UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:165 V
  • Input operation voltage (max)
    • OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:150 V
    • UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:230 V
  • Output operation voltage (max)
    • OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:127 V
    • UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:230 V
  • AC outlet types
    • OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:NEMA 5–15R
    • UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Type E
  • Battery recharge time
    • OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:5 h
    • UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:8 h
  • Housing material
    • OLS1000 uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:Metal
    • UT1500E-FR uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Plastic

Side by side

Differences highlightedShow differences only (on)
Comparison of OLS1000, UT1500E-FR
71 specifications
Features6 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers1 kVA1.5 kVA
Input operation voltage (min)Differs80 V165 V
Input operation voltage (max)Differs150 V230 V
Output operation voltage (min)Known for one100 VUnknown — not stated by the source
Output operation voltage (max)Differs127 V230 V
Surge energy ratingKnown for one440 JUnknown — not stated by the source
Transfer time (Line Mode to Battery Mode)Known for one0 msUnknown — not stated by the source
Efficiency (ECO mode)Known for one95%Unknown — not stated by the source
Input power factorKnown for one0.98Unknown — not stated by the source
Output power factorKnown for one0.9Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
ECO modeKnown for oneYesUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Overload capacity (1 minute)Known for one120%Unknown — not stated by the source
Overload capacity (10 seconds)Known for one120%Unknown — not stated by the source
Overload capacity - line mode (1 minute)Known for one120%Unknown — not stated by the source
Total Harmonic Distortion (THD) (linear load)Known for one3%Unknown — not stated by the source
Total Harmonic Distortion (THD) (non-linear load)Known for one5%Unknown — not stated by the source
Noise levelKnown for one45 dBUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneDigital Subscriber Line (DSL), Fax, Modem, Network, TelephoneUnknown — not stated by the source
Audible alarm modesDiffersAlarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacementAlarm when on battery, Fault, Low battery alarm, Overload alarm
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Response timeKnown for oneUnknown — not stated by the source4 ms
Ports & interfaces1 differ
AC outlet typesDiffersNEMA 5–15RType E
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Modem (RJ-11) portsKnown for one2Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one2Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Battery1 differ
Battery capacityKnown for one7 AhUnknown — not stated by the source
Battery voltageKnown for one12 VUnknown — not stated by the source
Typical backup time at full loadKnown for one5 minUnknown — not stated by the source
Typical backup time at half loadKnown for one15 minUnknown — not stated by the source
Battery recharge timeDiffers5 h8 h
Cold startKnown for oneYesUnknown — not stated by the source
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Design3 differ
Housing materialDiffersMetalPlastic
Cable lengthDiffers1.8 m1.2 m
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsDiffersBattery replacementYes
Operational conditions4 differ
Operating relative humidity (H-H)Differs20 - 90%0 - 90%
Storage relative humidity (H-H)Differs10 - 90%0 - 90%
Operating altitudeDiffers0 - 1500 m0 - 3000 m
Non-operating altitudeDiffers0 - 1500 m0 - 3000 m
Packaging contentidentical
Cables includedKnown for onePhone (RJ-11), USB cableUnknown — not stated by the source
Certificates1 differ
CertificationDiffersNOMCE
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers151 mm148 mm
DepthDiffers394 mm298 mm
HeightDiffers225 mm178 mm
WeightDiffers13.1 kg9.1 kg
Packaging dataidentical
Bundled softwareKnown for onePowerPanelUnknown — not stated by the source
Package widthKnown for one241 mmUnknown — not stated by the source
Package depthKnown for one510 mmUnknown — not stated by the source
Package heightKnown for one313 mmUnknown — not stated by the source
Package weightKnown for one14.6 kgUnknown — not stated by the source
Other featuresidentical
Nominal input voltageKnown for one120 VUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.