Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL8000E uninterruptible power supply (UPS) 8 kVA vs Vultech GS-1200VA uninterruptible power supply (UPS) 1.2 kVA 3 AC outlet(s)

Add a product
  • 15specifications compared
  • 13differ
  • 2identical
  • 35known for one product only

Key differences

  • Output power capacity
    • OL8000E uninterruptible power supply (UPS) 8 kVA:8 kVA
    • GS-1200VA uninterruptible power supply (UPS) 1.2 kVA 3 AC outlet(s):1.2 kVA
  • Input operation voltage (min)
    • OL8000E uninterruptible power supply (UPS) 8 kVA:120 V
    • GS-1200VA uninterruptible power supply (UPS) 1.2 kVA 3 AC outlet(s):165 V
  • Input frequency
    • OL8000E uninterruptible power supply (UPS) 8 kVA:40/70 Hz
    • GS-1200VA uninterruptible power supply (UPS) 1.2 kVA 3 AC outlet(s):50/60 Hz
  • Output operation voltage (max)
    • OL8000E uninterruptible power supply (UPS) 8 kVA:240 V
    • GS-1200VA uninterruptible power supply (UPS) 1.2 kVA 3 AC outlet(s):220 V
  • Power protection features
    • OL8000E uninterruptible power supply (UPS) 8 kVA:Short circuit
    • GS-1200VA uninterruptible power supply (UPS) 1.2 kVA 3 AC outlet(s):Overload
  • AC outlets quantity
    • OL8000E uninterruptible power supply (UPS) 8 kVA:10 AC outlet(s)
    • GS-1200VA uninterruptible power supply (UPS) 1.2 kVA 3 AC outlet(s):3 AC outlet(s)
  • Battery capacity
    • OL8000E uninterruptible power supply (UPS) 8 kVA:9 Ah
    • GS-1200VA uninterruptible power supply (UPS) 1.2 kVA 3 AC outlet(s):7 Ah
  • Typical backup time at full load
    • OL8000E uninterruptible power supply (UPS) 8 kVA:5.5 min
    • GS-1200VA uninterruptible power supply (UPS) 1.2 kVA 3 AC outlet(s):25 min

Side by side

Differences highlightedShow differences only (off)
Comparison of OL8000E, GS-1200VA
50 specifications
Features5 differ
Output power capacityDiffers8 kVA1.2 kVA
Output powerKnown for one7200 WUnknown — not stated by the source
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs120 V165 V
Input operation voltage (max)280 V280 V
Input frequencyDiffers40/70 Hz50/60 Hz
Output operation voltage (min)Known for one200 VUnknown — not stated by the source
Output operation voltage (max)Differs240 V220 V
Output frequency regulationKnown for one50/60 HzUnknown — not stated by the source
EfficiencyKnown for one95%Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Power protection featuresDiffersShort circuitOverload
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneBattery replacementUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Noise levelKnown for oneUnknown — not stated by the source45 dB
Ports & interfaces2 differ
AC outlet typesDiffersC13 coupler, C19 coupler, TerminalType F
Power plugKnown for oneTerminalUnknown — not stated by the source
AC outlets quantityDiffers10 AC outlet(s)3 AC outlet(s)
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Battery3 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery capacityDiffers9 Ah7 Ah
Battery voltage12 V12 V
Number of batteries supportedKnown for one20Unknown — not stated by the source
Typical backup time at full loadDiffers5.5 min25 min
Typical backup time at half loadKnown for one13.5 minUnknown — not stated by the source
Battery recharge timeDiffers5 h8 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Design2 differ
Form factorDiffersTowerCompact
Product colourDiffersBlackBlack, Grey
Cooling typeKnown for oneActiveUnknown — not stated by the source
Built-in fanKnown for oneYesUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneBattery replacementUnknown — not stated by the source
Weight & dimensions1 differ
WidthKnown for one265 mmUnknown — not stated by the source
DepthKnown for one660 mmUnknown — not stated by the source
HeightKnown for one616 mmUnknown — not stated by the source
WeightDiffers97 kg7.6 kg
Packaging dataidentical
Bundled softwareKnown for onePowerPanel BEUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 45 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source10 - 90%

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.