Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL6000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA vs CyberPower OL6KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA

Add a product
  • 59specifications compared
  • 7differ
  • 52identical
  • 1known for one product only

Key differences

  • AC outlets quantity
    • OL6000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:13 AC outlet(s)
    • OL6KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:1 AC outlet(s)
  • Rack capacity
    • OL6000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:8U
    • OL6KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:6U
  • Height
    • OL6000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:352 mm
    • OL6KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:264 mm
  • Weight
    • OL6000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:104.5 kg
    • OL6KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:102.5 kg
  • Package height
    • OL6000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:1028 mm
    • OL6KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:650 mm
  • Package weight
    • OL6000RT3UPDUTF uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:194.5 kg
    • OL6KRT3UHW uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:129.2 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of OL6000RT3UPDUTF, OL6KRT3UHW
60 specifications
Featuresidentical
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacity6 kVA6 kVA
Output power5400 W5400 W
WaveformSineSine
Input operation voltage (min)120 V120 V
Input operation voltage (max)280 V280 V
Input frequency40 - 70 Hz40 - 70 Hz
Output operation voltage (min)200 V200 V
Output operation voltage (max)240 V240 V
Surge energy rating2670 J2670 J
Power factor0.90.9
Input power factor0.990.99
Crest factor3:13:1
Output voltage Total Harmonic Distortion (THD)5%5%
EMI/RFI noise filteringYesYes
Noise level55 dB55 dB
Surge protectionYesYes
Surge protection featuresNetwork, TelephoneNetwork, Telephone
Power protection featuresInput fuse, Overload, Short circuitInput fuse, Overload, Short circuit
Audible alarm(s)YesYes
Audible alarm modesAlarm when on battery, Low battery alarm, Overload alarm, Battery replacementAlarm when on battery, Low battery alarm, Overload alarm, Battery replacement
Ports & interfaces2 differ
AC outlet typesDiffersTerminal, NEMA 5–20R, NEMA L6-20R, NEMA L6-30RTerminal
AC outlets quantityDiffers13 AC outlet(s)1 AC outlet(s)
USB portYesYes
Serial interfaceYesYes
Modem (RJ-11) ports22
Emergency Power Off (EPO) connectorYesYes
Batteryidentical
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacity12 VAh12 VAh
Number of batteries supported2020
Typical backup time at full load5 min5 min
Typical backup time at half load15 min15 min
Battery recharge time4 h4 h
Hot-swap batteryYesYes
Replacement battery cartridgeRB1270X20RB1270X20
Design1 differ
Form factorRackmount/TowerRackmount/Tower
Product colourBlackBlack
Housing materialSteelSteel
Rack capacityDiffers8U6U
Display typeLCDLCD
LED indicatorsPower, Battery replacementPower, Battery replacement
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 90%0 - 90%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Cables includedSerial, USB cableSerial, USB cable
Certificatesidentical
Compliance certificatesRoHSRoHS
Sustainabilityidentical
Sustainability certificatesENERGY STARENERGY STAR
Safety regulation & standardsidentical
SafetyUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class AUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
Weight & dimensions2 differ
Width433 mm433 mm
Depth820 mm820 mm
HeightDiffers352 mm264 mm
WeightDiffers104.5 kg102.5 kg
Packaging data2 differ
Package width620 mm620 mm
Package depth1120 mm1120 mm
Package heightDiffers1028 mm650 mm
Package weightDiffers194.5 kg129.2 kg