Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL6000RT3U uninterruptible power supply (UPS) 6 kVA vs Dell PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s)

Add a product
  • 23specifications compared
  • 17differ
  • 6identical
  • 37known for one product only

Key differences

  • Output power
    • OL6000RT3U uninterruptible power supply (UPS) 6 kVA:5400 W
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):500 W
  • Input operation voltage (min)
    • OL6000RT3U uninterruptible power supply (UPS) 6 kVA:120 V
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):160 V
  • Input operation voltage (max)
    • OL6000RT3U uninterruptible power supply (UPS) 6 kVA:280 V
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):286 V
  • Output operation voltage (min)
    • OL6000RT3U uninterruptible power supply (UPS) 6 kVA:200 V
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):198 V
  • Output operation voltage (max)
    • OL6000RT3U uninterruptible power supply (UPS) 6 kVA:240 V
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):264 V
  • Surge protection features
    • OL6000RT3U uninterruptible power supply (UPS) 6 kVA:Network, Telephone
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):Network
  • AC outlet types
    • OL6000RT3U uninterruptible power supply (UPS) 6 kVA:NEMA L6-20R, NEMA L6-30R
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):C13 coupler
  • AC outlets quantity
    • OL6000RT3U uninterruptible power supply (UPS) 6 kVA:4 AC outlet(s)
    • PowerEdge 500W uninterruptible power supply (UPS) 6 AC outlet(s):6 AC outlet(s)

Side by side

Differences highlightedShow differences only (on)
Comparison of OL6000RT3U, 500W
60 specifications
Features6 differ
Output power capacityKnown for one6 kVAUnknown — not stated by the source
Output powerDiffers5400 W500 W
Input operation voltage (min)Differs120 V160 V
Input operation voltage (max)Differs280 V286 V
Input frequencyKnown for one40/70 HzUnknown — not stated by the source
Output operation voltage (min)Differs200 V198 V
Output operation voltage (max)Differs240 V264 V
Power factorKnown for one0.9Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Noise levelKnown for one55 dBUnknown — not stated by the source
Surge protection featuresDiffersNetwork, TelephoneNetwork
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneBattery replacementUnknown — not stated by the source
Surge energy ratingKnown for oneUnknown — not stated by the source2400 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Ports & interfaces2 differ
AC outlet typesDiffersNEMA L6-20R, NEMA L6-30RC13 coupler
AC outlets quantityDiffers4 AC outlet(s)6 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Battery2 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of battery cellsKnown for one20Unknown — not stated by the source
Typical backup time at full loadDiffers5.3 min5 min
Typical backup time at half loadDiffers15.8 min12 min
Battery recharge timeKnown for one4 hUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmount/TowerTower
Housing materialKnown for oneSteelUnknown — not stated by the source
Rack capacityKnown for one6UUnknown — not stated by the source
Cable lengthKnown for one1.8 mUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationDiffersETLFCC, CNS, AS/NZS, KN22, GB, EN, IEC, ANSI, CISPR 22
Weight & dimensions4 differ
WidthDiffers433 mm170 mm
DepthDiffers660 mm380 mm
HeightDiffers264 mm216 mm
WeightDiffers100 kg11.6 kg
Packaging data1 differ
Bundled softwareKnown for onePowerPanelUnknown — not stated by the source
Package weightDiffers124.8 kg13.8 kg
Other featuresidentical
Battery typeKnown for one12V/10AHUnknown — not stated by the source
Output connectionsKnown for one2 x NEMA L6-20R & 2 x NEMA L6-30RUnknown — not stated by the source
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Management platformKnown for oneSNMP / HTTPUnknown — not stated by the source
Package dimensions (WxDxH)Known for one600 x 900 x 638 mmUnknown — not stated by the source
Number of phasesKnown for oneUnknown — not stated by the source1

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.