Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL6000ERT3UP uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA vs Dell Smart-UPS 1500VA

Add a product
  • 38specifications compared
  • 27differ
  • 11identical
  • 36known for one product only

Key differences

  • UPS topology
    • OL6000ERT3UP uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Double-conversion (Online)
    • Smart-UPS 1500VA:Line-Interactive
  • Output power capacity
    • OL6000ERT3UP uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:6 kVA
    • Smart-UPS 1500VA:1.5 kVA
  • Output power
    • OL6000ERT3UP uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:5400 W
    • Smart-UPS 1500VA:1000 W
  • Waveform
    • OL6000ERT3UP uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Pure sine
    • Smart-UPS 1500VA:Sine
  • Input operation voltage (min)
    • OL6000ERT3UP uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:180 V
    • Smart-UPS 1500VA:160 V
  • Input operation voltage (max)
    • OL6000ERT3UP uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:280 V
    • Smart-UPS 1500VA:286 V
  • Output operation voltage (min)
    • OL6000ERT3UP uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:200 V
    • Smart-UPS 1500VA:220 V
  • Surge energy rating
    • OL6000ERT3UP uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:2430 J
    • Smart-UPS 1500VA:459 J

Side by side

Differences highlightedShow differences only (on)
Comparison of OL6000ERT3UP, Smart-UPS 1500VA
74 specifications
Features10 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers6 kVA1.5 kVA
Output powerDiffers5400 W1000 W
WaveformDiffersPure sineSine
Input operation voltage (min)Differs180 V160 V
Input operation voltage (max)Differs280 V286 V
Output operation voltage (min)Differs200 V220 V
Maximum currentKnown for one30 AUnknown — not stated by the source
Surge energy ratingDiffers2430 J459 J
EfficiencyKnown for one95%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Output power factorKnown for one0.9Unknown — not stated by the source
Power Factor Correction (PFC) typeKnown for oneActiveUnknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Total Harmonic Distortion (THD) (linear load)Known for one3%Unknown — not stated by the source
Total Harmonic Distortion (THD) (non-linear load)Known for one5%Unknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Noise levelKnown for one65 dBUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresDiffersOverload, Short circuitOverload
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesDiffersAlarm when on battery, Fault, Low battery alarm, Overload alarmBattery replacement
Output voltage regulationKnown for oneUnknown — not stated by the source5%
Ports & interfaces4 differ
AC outlet typesDiffersC13 coupler, C19 coupler, TerminalC13 coupler
Power plugDiffersTerminalC14 coupler
AC outlets quantityDiffers11 AC outlet(s)4 AC outlet(s)
USB portKnown for oneYesUnknown — not stated by the source
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Ethernet LAN (RJ-45) portsDiffers21
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Number of output IEC jumpersKnown for oneUnknown — not stated by the source2
Battery2 differ
Battery capacityKnown for one7 AhUnknown — not stated by the source
Battery voltageKnown for one120 VUnknown — not stated by the source
Number of batteries supportedDiffers21
Typical backup time at full loadKnown for one5 minUnknown — not stated by the source
Typical backup time at half loadKnown for one15 minUnknown — not stated by the source
Battery recharge timeDiffers4 h3 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Replacement battery cartridgeKnown for oneRBP0073Unknown — not stated by the source
Design2 differ
Form factorDiffersRackmount/TowerRackmount
Housing materialKnown for oneMetalUnknown — not stated by the source
Rack capacityDiffers6U2U
Cable lengthKnown for oneUnknown — not stated by the source2.44 m
Cooling typeKnown for oneUnknown — not stated by the sourceActive
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Packaging contentidentical
Rack mount kitKnown for oneYesUnknown — not stated by the source
ManualKnown for oneUnknown — not stated by the sourceYes
Certificatesidentical
CertificationKnown for oneCE , C-TickUnknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers433 mm432 mm
DepthDiffers820 mm457 mm
HeightDiffers264 mm89 mm
WeightDiffers104.5 kg28.6 kg
Packaging data4 differ
Package widthDiffers600 mm594 mm
Package depthDiffers1115 mm603 mm
Package heightDiffers640 mm251 mm
Package weightDiffers131 kg31.9 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other featuresidentical
BypassKnown for oneAutomatic Bypass , Manual BypassUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceC-tick, CE, EN62040-1, EN62040-2, EN60950-1, GOST, VDE

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.