Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA vs CyberPower RT650 uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA

Add a product
  • 47specifications compared
  • 31differ
  • 16identical
  • 23known for one product only

Key differences

  • UPS topology
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Double-conversion (Online)
    • RT650 uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA:Standby (Offline)
  • Output power capacity
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • RT650 uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA:0.65 kVA
  • Output power
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2700 W
    • RT650 uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA:400 W
  • Input operation voltage (min)
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:120 V
    • RT650 uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA:96 V
  • Input operation voltage (max)
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:280 V
    • RT650 uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA:141 V
  • Input frequency
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:40 - 70 Hz
    • RT650 uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA:47/63 Hz
  • Output operation voltage (max)
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
    • RT650 uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA:120 V
  • Surge energy rating
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:1335 J
    • RT650 uninterruptible power supply (UPS) Standby (Offline) 0.65 kVA:480 J

Side by side

Differences highlightedShow differences only (off)
Comparison of OL3000RTXL2UHV, RT650
70 specifications
Features10 differ
UPS topologyDiffersDouble-conversion (Online)Standby (Offline)
Output power capacityDiffers3 kVA0.65 kVA
Output powerDiffers2700 W400 W
WaveformSineSine
Input operation voltage (min)Differs120 V96 V
Input operation voltage (max)Differs280 V141 V
Input frequencyDiffers40 - 70 Hz47/63 Hz
Output operation voltage (min)Known for one200 VUnknown — not stated by the source
Output operation voltage (max)Differs240 V120 V
Surge energy ratingDiffers1335 J480 J
Power factorKnown for one0.9Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
EMI/RFI noise filteringYesYes
Noise levelDiffers50 dB40.6 dB
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresNetwork, TelephoneNetwork, Telephone
Power protection featuresDiffersOverload, Short circuitShort circuit
Audible alarm(s)YesYes
Audible alarm modesAlarm when on battery, Low battery alarm, Overload alarm, Battery replacementAlarm when on battery, Low battery alarm, Overload alarm, Battery replacement
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceNo
Response timeKnown for oneUnknown — not stated by the source4 ms
Ports & interfaces4 differ
AC outlet typesDiffersNEMA L6-20R, NEMA L6-30RNEMA 5–15R
Power plugDiffersNEMA L6-20PNEMA 5-15P
AC outlets quantityDiffers3 AC outlet(s)6 AC outlet(s)
USB portYesYes
Serial interfaceYesYes
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Modem (RJ-11) portsDiffers21
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Battery5 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacityDiffers12 VAh7 Ah
Number of batteries supportedDiffers61
Typical backup time at full loadDiffers4 min2 min
Typical backup time at half loadDiffers11 min10 min
Battery recharge timeDiffers4 h8 h
Hot-swap batteryYesYes
Replacement battery cartridgeKnown for oneRB1290X6AUnknown — not stated by the source
Battery voltageKnown for oneUnknown — not stated by the source12 V
Design3 differ
Form factorDiffersRackmount/TowerMini Tower
Product colourBlackBlack
Housing materialKnown for oneSteelUnknown — not stated by the source
Rack capacityKnown for one2UUnknown — not stated by the source
Cable lengthDiffers3.04 m1.8 m
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsDiffersPower, Battery replacementPower
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 35 °C
Storage temperature (T-T)Differs-20 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Packaging content1 differ
Rack mount kitKnown for oneYesUnknown — not stated by the source
Cables includedDiffersPhone (RJ-11), Serial, USB cableUSB cable
ManualYesYes
Certificatesidentical
Compliance certificatesRoHSRoHS
Sustainabilityidentical
Sustainability certificatesENERGY STARENERGY STAR
Safety regulation & standards1 differ
SafetyDiffersUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class AUL1778, cUL 107, FCC DOC Class B
Weight & dimensions4 differ
WidthDiffers433 mm91.4 mm
DepthDiffers600 mm279.4 mm
HeightDiffers88 mm165 mm
WeightDiffers31 kg4 kg
Packaging dataidentical
Warranty cardKnown for oneYesUnknown — not stated by the source
Package widthKnown for one590 mmUnknown — not stated by the source
Package depthKnown for one890 mmUnknown — not stated by the source
Package heightKnown for one240 mmUnknown — not stated by the source
Package weightKnown for one39.4 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons