Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL3000EXL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA vs Vertiv GXT4-5000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA

Add a product
  • 22specifications compared
  • 12differ
  • 10identical
  • 37known for one product only

Key differences

  • Output power capacity
    • OL3000EXL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • GXT4-5000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:5 kVA
  • Output power
    • OL3000EXL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2700 W
    • GXT4-5000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:4000 W
  • Input operation voltage (max)
    • OL3000EXL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:280 V
    • GXT4-5000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:208 V
  • Output operation voltage (min)
    • OL3000EXL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:200 V
    • GXT4-5000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:120 V
  • Output operation voltage (max)
    • OL3000EXL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
    • GXT4-5000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:208 V
  • AC outlet types
    • OL3000EXL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:C13 coupler, C19 coupler
    • GXT4-5000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:Terminal
  • Form factor
    • OL3000EXL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Tower
    • GXT4-5000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:Rackmount
  • LED indicators
    • OL3000EXL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Power, Battery replacement
    • GXT4-5000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA:Yes

Side by side

Differences highlightedShow differences only (on)
Comparison of OL3000EXL, GXT4-5000RT208
59 specifications
Features5 differ
Output power capacityDiffers3 kVA5 kVA
Output powerDiffers2700 W4000 W
Input operation voltage (max)Differs280 V208 V
Output operation voltage (min)Differs200 V120 V
Output operation voltage (max)Differs240 V208 V
Output frequency regulationKnown for one50/60 HzUnknown — not stated by the source
Response timeKnown for one0 msUnknown — not stated by the source
EfficiencyKnown for one93%Unknown — not stated by the source
Surge protectionKnown for oneNoUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Power protection featuresKnown for oneOverload, Short circuitUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneBattery replacementUnknown — not stated by the source
Management protocolsKnown for oneSNMP/HTTPUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Maximum currentKnown for oneUnknown — not stated by the source30 A
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Ports & interfaces1 differ
AC outlet typesDiffersC13 coupler, C19 couplerTerminal
AC outlets quantityKnown for one9 AC outlet(s)Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceTerminal
Batteryidentical
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one9 minUnknown — not stated by the source
Battery recharge timeKnown for one4 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Design2 differ
Form factorDiffersTowerRackmount
Cooling typeKnown for oneActiveUnknown — not stated by the source
LED indicatorsDiffersPower, Battery replacementYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Weight & dimensions4 differ
WidthDiffers212 mm430 mm
DepthDiffers414 mm662 mm
HeightDiffers338 mm173 mm
WeightDiffers30 kg69.9 kg
Packaging dataidentical
Bundled softwareKnown for onePowerPanel Business EditionUnknown — not stated by the source
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 50 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL 1778, c-U
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceFCC A, IEEE/ANSI C62.41 A

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.