Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA vs CyberPower OL8000ERT3UD uninterruptible power supply (UPS) 8 kVA

Add a product
  • 25specifications compared
  • 9differ
  • 16identical
  • 8known for one product only

Key differences

  • Output power capacity
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:2 kVA
    • OL8000ERT3UD uninterruptible power supply (UPS) 8 kVA:8 kVA
  • Output power
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:1800 W
    • OL8000ERT3UD uninterruptible power supply (UPS) 8 kVA:7200 W
  • AC outlets quantity
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:9 AC outlet(s)
    • OL8000ERT3UD uninterruptible power supply (UPS) 8 kVA:4 AC outlet(s)
  • Typical backup time at full load
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:4 min
    • OL8000ERT3UD uninterruptible power supply (UPS) 8 kVA:8.5 min
  • Typical backup time at half load
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:11 min
    • OL8000ERT3UD uninterruptible power supply (UPS) 8 kVA:22 min
  • Battery recharge time
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:4 h
    • OL8000ERT3UD uninterruptible power supply (UPS) 8 kVA:5 h
  • Rack capacity
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:2U
    • OL8000ERT3UD uninterruptible power supply (UPS) 8 kVA:3U
  • Depth
    • OL2000ERTXL2U uninterruptible power supply (UPS) 2 kVA:600 mm
    • OL8000ERT3UD uninterruptible power supply (UPS) 8 kVA:660 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of OL2000ERTXL2U, OL8000ERT3UD
33 specifications
Features2 differ
Output power capacityDiffers2 kVA8 kVA
Output powerDiffers1800 W7200 W
Surge protection featuresKnown for oneUnknown — not stated by the sourceFax, Modem, Network, Telephone
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload, Short circuit
Ports & interfaces1 differ
Power plugKnown for oneC14 couplerUnknown — not stated by the source
AC outlets quantityDiffers9 AC outlet(s)4 AC outlet(s)
Battery3 differ
Typical backup time at full loadDiffers4 min8.5 min
Typical backup time at half loadDiffers11 min22 min
Battery recharge timeDiffers4 h5 h
Cold startKnown for oneYesUnknown — not stated by the source
Design1 differ
Rack capacityDiffers2U3U
LED indicatorsKnown for oneYesUnknown — not stated by the source
Weight & dimensions2 differ
DepthDiffers600 mm660 mm
HeightDiffers88 mm132 mm
WeightKnown for one30 kgUnknown — not stated by the source
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other featuresidentical
Output connectionsKnown for oneUnknown — not stated by the source(2) IEC C13, (1) IEC C19

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons