Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL1500RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA vs CyberPower OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA

Add a product
  • 65specifications compared
  • 21differ
  • 44identical
  • 2known for one product only

Key differences

  • Output power capacity
    • OL1500RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:1.5 kVA
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
  • Output power
    • OL1500RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:1350 W
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2700 W
  • Input operation voltage (min)
    • OL1500RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:60 V
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:120 V
  • Input operation voltage (max)
    • OL1500RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:150 V
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:280 V
  • Output operation voltage (min)
    • OL1500RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:100 V
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:200 V
  • Output operation voltage (max)
    • OL1500RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:125 V
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
  • Surge energy rating
    • OL1500RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:1780 J
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:1335 J
  • Power protection features
    • OL1500RTXL2UN uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:Short circuit
    • OL3000RTXL2UHV uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Overload, Short circuit

Side by side

Differences highlightedShow differences only (on)
Comparison of OL1500RTXL2UN, OL3000RTXL2UHV
67 specifications
Features9 differ
Output power capacityDiffers1.5 kVA3 kVA
Output powerDiffers1350 W2700 W
Input operation voltage (min)Differs60 V120 V
Input operation voltage (max)Differs150 V280 V
Output operation voltage (min)Differs100 V200 V
Output operation voltage (max)Differs125 V240 V
Surge energy ratingDiffers1780 J1335 J
Power protection featuresDiffersShort circuitOverload, Short circuit
Audible alarm(s)DiffersNoYes
Ports & interfaces3 differ
AC outlet typesDiffersNEMA 5–15RNEMA L6-20R, NEMA L6-30R
Power plugDiffersNEMA 5-15PNEMA L6-20P
AC outlets quantityDiffers8 AC outlet(s)3 AC outlet(s)
RS-232 portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one2Unknown — not stated by the source
Battery3 differ
Number of batteries supportedDiffers36
Typical backup time at full loadDiffers3 min4 min
Replacement battery cartridgeDiffersRB1290X3LRB1290X6A
Safety regulation & standards1 differ
SafetyDiffersUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class BUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
Weight & dimensions2 differ
DepthDiffers430 mm600 mm
WeightDiffers18 kg31 kg
Packaging data3 differ
Package widthDiffers550 mm590 mm
Package depthDiffers590 mm890 mm
Package weightDiffers24.4 kg39.4 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.