Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA vs CyberPower PR1500ELCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA

Add a product
  • 36specifications compared
  • 21differ
  • 15identical
  • 37known for one product only

Key differences

  • UPS topology
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:Double-conversion (Online)
    • PR1500ELCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Line-Interactive
  • Input operation voltage (min)
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:100 V
    • PR1500ELCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:151 V
  • Input operation voltage (max)
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:125 V
    • PR1500ELCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:301 V
  • Input frequency
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:40/70 Hz
    • PR1500ELCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:50/60 Hz
  • Output operation voltage (min)
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:100 V
    • PR1500ELCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:230 V
  • Output operation voltage (max)
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:125 V
    • PR1500ELCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:230 V
  • Response time
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:0 ms
    • PR1500ELCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:4 ms
  • AC outlet types
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:NEMA 5–15R
    • PR1500ELCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:C13 coupler

Side by side

Differences highlightedShow differences only (on)
Comparison of OL1500RTXL2U, PR1500ELCD
73 specifications
Features7 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
WaveformKnown for oneUnknown — not stated by the sourcePure sine
Input operation voltage (min)Differs100 V151 V
Input operation voltage (max)Differs125 V301 V
Input frequencyDiffers40/70 Hz50/60 Hz
Output operation voltage (min)Differs100 V230 V
Output operation voltage (max)Differs125 V230 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Maximum currentKnown for oneUnknown — not stated by the source10 A
Surge energy ratingKnown for oneUnknown — not stated by the source405 J
Response timeDiffers0 ms4 ms
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Fault, Low battery alarm, Overload alarm
EfficiencyKnown for one93%Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Noise levelKnown for one50 dBUnknown — not stated by the source
Surge protection featuresKnown for oneNetworkUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5–15RC13 coupler
Power plugDiffersNEMA 1-15PC14 coupler
Number of output IEC jumpersKnown for oneUnknown — not stated by the source1
USB portKnown for oneUnknown — not stated by the sourceYes
Modem (RJ-11) portsKnown for one2Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one2Unknown — not stated by the source
Battery3 differ
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Typical backup time at full loadDiffers3 min5 min
Typical backup time at half loadDiffers9 min17 min
Battery recharge timeDiffers5 h8 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Number of battery cellsKnown for one3Unknown — not stated by the source
Replacement battery cartridgeKnown for oneRB1290X3Unknown — not stated by the source
Design2 differ
Form factorDiffersRackmount/TowerTower
Housing materialDiffersSteelMetal
LED indicatorsKnown for oneUnknown — not stated by the sourceError, Operation
Rack capacityKnown for one2UUnknown — not stated by the source
Cable lengthKnown for one3.05 mUnknown — not stated by the source
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceUSB cable
Certificates1 differ
CertificationDiffersUL1778, CSA C22.2 NO.107.3-05, FCC DOC ACE, EAC, RCM, RoHS
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers433 mm170 mm
DepthDiffers430 mm432 mm
HeightDiffers88 mm221 mm
WeightDiffers18 kg25.1 kg
Packaging data1 differ
Package widthKnown for oneUnknown — not stated by the source316 mm
Package depthKnown for oneUnknown — not stated by the source579 mm
Package heightKnown for oneUnknown — not stated by the source360 mm
Package weightDiffers24.4 kg27 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source8504408590
Country of originKnown for oneUnknown — not stated by the sourceChina
Other featuresidentical
Compatible operating systemsKnown for oneUnknown — not stated by the sourceWindows 7 / Vista / XP / 2000, Server 2003 / 2008, Linux
Overload protectionKnown for oneUnknown — not stated by the sourceYes
Battery typeKnown for one12V/9AhUnknown — not stated by the source
Package dimensions (WxDxH)Known for one550 x 590 x 240 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons