The CyberPower M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA has 0.4 kVA more output power capacity than the Salicru SLC-700-TWIN RT2 (1.1 kVA vs 0.7 kVA). The CyberPower M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA has 180 W more output power than the Salicru SLC-700-TWIN RT2 (880 W vs 700 W). The Salicru SLC-700-TWIN RT2 has 22 V more input operation voltage (min) than the CyberPower M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA (110 V vs 88 V). UPS topology: Line-Interactive on the CyberPower M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA, Double-conversion (Online) on the Salicru SLC-700-TWIN RT2. Input frequency: 60 Hz on the CyberPower M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA, 50/60 Hz on the Salicru SLC-700-TWIN RT2.

  • UPS topology
    • M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA:Line-Interactive
    • SLC-700-TWIN RT2:Double-conversion (Online)
  • Output power capacity
    • M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA:1.1 kVA
    • SLC-700-TWIN RT2:0.7 kVA
  • Output power
    • M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA:880 W
    • SLC-700-TWIN RT2:700 W
  • Input operation voltage (min)
    • M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA:88 V
    • SLC-700-TWIN RT2:110 V
  • Input operation voltage (max)
    • M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA:150 V
    • SLC-700-TWIN RT2:300 V
  • Input frequency
    • M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA:60 Hz
    • SLC-700-TWIN RT2:50/60 Hz
  • Output operation voltage (min)
    • M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA:120 V
    • SLC-700-TWIN RT2:200 V
  • Output operation voltage (max)
    • M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA:120 V
    • SLC-700-TWIN RT2:240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of M1100XL, 698CA000001
79 specifications
B

Salicru

SLC-700-TWIN RT2

Model 698CA000001

View product
Features10 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1.1 kVA0.7 kVA
Output powerDiffers880 W700 W
Input operation voltage (min)Differs88 V110 V
Input operation voltage (max)Differs150 V300 V
Input frequencyDiffers60 Hz50/60 Hz
Output operation voltage (min)Differs120 V200 V
Output operation voltage (max)Differs120 V240 V
Output frequencyDiffers60 Hz50/60 Hz
Automatic Voltage Regulation (AVR)YesYes
Power factorKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Overload capacity (10 minutes)Known for oneUnknown — not stated by the source110%
Overload capacity (5 minute)Known for oneUnknown — not stated by the source130%
Overload capacity (1 minute)Known for oneUnknown — not stated by the source130%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Total Harmonic Distortion (THD) (linear load)Known for oneUnknown — not stated by the source2%
Total Harmonic Distortion (THD) (non-linear load)Known for oneUnknown — not stated by the source4%
Noise levelKnown for oneUnknown — not stated by the source55 dB
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceDigital Subscriber Line (DSL), Fax, Modem
Power protection featuresDiffersOverloadUnder current, Under voltage
Input frequency converterKnown for oneUnknown — not stated by the sourceYes
Synchronisation with mainsKnown for oneUnknown — not stated by the source3 Hz
Synchronisation without mainsKnown for oneUnknown — not stated by the source0.1 Hz
Temperature voltage compensationKnown for oneUnknown — not stated by the sourceYes
WaveformKnown for onePseudo sineUnknown — not stated by the source
Maximum currentKnown for one10 AUnknown — not stated by the source
Surge energy ratingKnown for one1445 JUnknown — not stated by the source
Transfer time (Line Mode to Battery Mode)Known for one10 msUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Fault, Low battery alarm, Overload alarmUnknown — not stated by the source
Socket circuit breakerKnown for oneYesUnknown — not stated by the source
Ports & interfaces3 differ
AC outlet typesDiffersNEMA 5-15RC13 coupler
Power plugDiffersNEMA 5-15P-HGC14 coupler
AC outlets quantityDiffers6 AC outlet(s)8 AC outlet(s)
USB portYesYes
Serial interfaceYesYes
Serial interface typeRS-232RS-232
RS-232 ports11
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
SmartSlotKnown for oneUnknown — not stated by the sourceYes
Programmable socketsKnown for oneUnknown — not stated by the sourceYes
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
USB port typeKnown for oneUSB Type-BUnknown — not stated by the source
Battery2 differ
Battery technologyDiffersSealed Lead Acid (VRLA)Lead-Calcium (Pb-Ca)
Battery recharge timeDiffers8 h3 h
Cold startKnown for oneUnknown — not stated by the sourceYes
Charge typeKnown for oneUnknown — not stated by the sourceI/U
Battery capacityKnown for one9 AhUnknown — not stated by the source
Battery voltageKnown for one12 VUnknown — not stated by the source
Number of batteries supportedKnown for one3Unknown — not stated by the source
Typical backup time at full loadKnown for one10 minUnknown — not stated by the source
Typical backup time at half loadKnown for one25 minUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Design2 differ
Form factorDiffersMini TowerRackmount/Tower
Product colourDiffersWhiteBlack
Rack capacityKnown for oneUnknown — not stated by the source2U
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Display typeLCDLCD
Cable lengthKnown for one1.8 mUnknown — not stated by the source
LED indicatorsKnown for onePowerUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeDiffers0 - 3000 m0 - 2400 m
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Safety regulation & standards1 differ
SafetyDiffersUL1778, CSA, FCC 15 A (EMI), UL60601-1EN 62040-1:2008
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceEN 62040-2:2006(C2), EN 62040-3:2011, ISO 9001, ISO 14001
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers220 mm438 mm
DepthDiffers431 mm405 mm
HeightDiffers170 mm88 mm
WeightDiffers24.5 kg14.1 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85078000
Other featuresidentical
Compatible operating systemsKnown for oneUnknown — not stated by the sourceWindows, Linux, Mac
Packaging contentidentical
Cables includedKnown for oneSerial, USB cableUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.