Product comparison · 2 uninterruptible power supplies (upss)

CyberPower Intelligent LCD vs Legrand Onduleur Keor multiplug avec multiprise de sortie - 800 VA

Add a product
  • 26specifications compared
  • 18differ
  • 8identical
  • 46known for one product only

Key differences

  • UPS topology
    • Intelligent LCD:Line-Interactive
    • Onduleur Keor multiplug avec multiprise de sortie - 800 VA:Standby (Offline)
  • Output power capacity
    • Intelligent LCD:1.35 kVA
    • Onduleur Keor multiplug avec multiprise de sortie - 800 VA:0.8 kVA
  • Output power
    • Intelligent LCD:810 W
    • Onduleur Keor multiplug avec multiprise de sortie - 800 VA:480 W
  • Input operation voltage (min)
    • Intelligent LCD:165 V
    • Onduleur Keor multiplug avec multiprise de sortie - 800 VA:180 V
  • Input operation voltage (max)
    • Intelligent LCD:265 V
    • Onduleur Keor multiplug avec multiprise de sortie - 800 VA:270 V
  • Input frequency
    • Intelligent LCD:50/60 Hz
    • Onduleur Keor multiplug avec multiprise de sortie - 800 VA:47/63 Hz
  • Modem (RJ-11) ports
    • Intelligent LCD:2
    • Onduleur Keor multiplug avec multiprise de sortie - 800 VA:1
  • Ethernet LAN (RJ-45) ports
    • Intelligent LCD:2
    • Onduleur Keor multiplug avec multiprise de sortie - 800 VA:1

Side by side

Differences highlightedShow differences only (off)
Comparison of Intelligent LCD, Onduleur Keor multiplug avec multiprise de sortie - 800 VA
72 specifications
Features6 differ
UPS topologyDiffersLine-InteractiveStandby (Offline)
Output power capacityDiffers1.35 kVA0.8 kVA
Output powerDiffers810 W480 W
Input operation voltage (min)Differs165 V180 V
Input operation voltage (max)Differs265 V270 V
Input frequencyDiffers50/60 Hz47/63 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source207 V
Output operation voltage (max)Known for oneUnknown — not stated by the source253 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Number of input phases11
Number of output phases11
Power protection featuresKnown for oneUnknown — not stated by the sourceOvercharge, Overdischarge, Overheating, Short circuit
Potential-free outputKnown for oneUnknown — not stated by the sourceNo
Auto-restartKnown for oneUnknown — not stated by the sourceYes
Detachable power cordKnown for oneUnknown — not stated by the sourceYes
Power source typeKnown for oneUnknown — not stated by the sourceAC
WaveformKnown for oneSineUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for one10 AUnknown — not stated by the source
Surge energy ratingKnown for one1215 JUnknown — not stated by the source
Response timeKnown for one4 msUnknown — not stated by the source
Power factorKnown for one0.6Unknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesKnown for oneUnknown — not stated by the sourceType E
AC outlets quantity6 AC outlet(s)6 AC outlet(s)
Number of type F outputsKnown for oneUnknown — not stated by the source6
USB 2.0 ports quantity11
Modem (RJ-11) portsDiffers21
Ethernet LAN (RJ-45) portsDiffers21
Battery3 differ
Battery capacityDiffers8 Ah9 Ah
Battery voltage12 V12 V
Number of batteries supportedDiffers21
Typical backup time at full loadDiffers2 min10 min
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at half loadKnown for one10 minUnknown — not stated by the source
Design2 differ
Form factorDiffersTowerCompact
Product colourDiffersBlackBlack, White
LED indicatorsYesYes
Cable lengthKnown for one1.83 mUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 90%0 - 90%
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15001 mUnknown — not stated by the source
Certificates1 differ
CertificationDiffersCE, GOST, C-TickEN62040-1, EN62040-2
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers100 mm250 mm
DepthDiffers371 mm97.5 mm
HeightDiffers249 mm229 mm
WeightDiffers11.5 kg4 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source250 mm
Package depthKnown for oneUnknown — not stated by the source5.58 mm
Package heightKnown for oneUnknown — not stated by the source229 mm
Package weightKnown for oneUnknown — not stated by the source4.08 kg
Bundled softwareKnown for onePowerPanel Personal EditionUnknown — not stated by the source
Logistics dataidentical
Products per palletKnown for oneUnknown — not stated by the source48 pc(s)
Pallet net heightKnown for oneUnknown — not stated by the source77 cm
Pallet net lengthKnown for oneUnknown — not stated by the source100 cm
Pallet net weightKnown for oneUnknown — not stated by the source222.6 kg
Pallet net widthKnown for oneUnknown — not stated by the source120 cm
Master (outer) case widthKnown for oneUnknown — not stated by the source306 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source332 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source345 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source9.28 kg
Products per master (outer) caseKnown for oneUnknown — not stated by the source2 pc(s)
Other featuresidentical
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.