Product comparison · 2 uninterruptible power supplies (upss)

CyberPower CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA vs Manhattan Line Interactive

Add a product
  • 25specifications compared
  • 19differ
  • 6identical
  • 19known for one product only

Key differences

  • Output power capacity
    • CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA:1.5 kVA
    • Line Interactive:1.8 kVA
  • Output power
    • CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA:900 W
    • Line Interactive:1200 W
  • Input operation voltage (min)
    • CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA:90 V
    • Line Interactive:115 V
  • Input frequency
    • CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA:60 Hz
    • Line Interactive:50/60 Hz
  • Output operation voltage (min)
    • CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA:120 V
    • Line Interactive:115 V
  • Surge energy rating
    • CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA:1030 J
    • Line Interactive:1120 J
  • AC outlet types
    • CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA:NEMA 5–15P
    • Line Interactive:NEMA 5–15R
  • AC outlets quantity
    • CP1500PFCLCDTAA uninterruptible power supply (UPS) 1.5 kVA:10 AC outlet(s)
    • Line Interactive:8 AC outlet(s)

Side by side

Differences highlightedShow differences only (on)
Comparison of CP1500PFCLCDTAA, Line Interactive
44 specifications
Features6 differ
Output power capacityDiffers1.5 kVA1.8 kVA
Output powerDiffers900 W1200 W
Input operation voltage (min)Differs90 V115 V
Input operation voltage (max)Known for one139 VUnknown — not stated by the source
Input frequencyDiffers60 Hz50/60 Hz
Output operation voltage (min)Differs120 V115 V
Output operation voltage (max)Known for one120 VUnknown — not stated by the source
Surge energy ratingDiffers1030 J1120 J
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceNetwork, Telephone
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Ports & interfaces5 differ
AC outlet typesDiffersNEMA 5–15PNEMA 5–15R
AC outlets quantityDiffers10 AC outlet(s)8 AC outlet(s)
USB 2.0 ports quantityDiffers21
Serial ports quantityKnown for one1Unknown — not stated by the source
Modem (RJ-11) portsDiffers21
Ethernet LAN (RJ-45) portsDiffers21
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15R
RS-232 portsKnown for oneUnknown — not stated by the source1
Battery2 differ
Number of battery cellsKnown for one2Unknown — not stated by the source
Typical backup time at full loadDiffers2 min12 min
Typical backup time at half loadDiffers11 min5 min
Replacement battery cartridgeKnown for oneBB Battery - HR1234WUnknown — not stated by the source
Design3 differ
Form factorDiffersTowerRackmount
Cable lengthDiffers1.5 m1.8 m
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsDiffersPower, Power failYes
Rack capacityKnown for oneUnknown — not stated by the source3U
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 40 °C
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneUL1778, cUL 107.3, FCC DOC BUnknown — not stated by the source
Weight & dimensions2 differ
WidthDiffers99 mm482.6 mm
DepthDiffers361 mm609.6 mm
HeightKnown for one264 mmUnknown — not stated by the source
WeightKnown for one11.2 kgUnknown — not stated by the source
Packaging dataidentical
Bundled softwareKnown for onePowerPanel Personal EditionUnknown — not stated by the source
Other featuresidentical
Battery typeKnown for one12V/8.5AHUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons