Product comparison · 2 uninterruptible power supplies (upss)

CyberPower CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA vs CyberPower PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA

Add a product
  • 24specifications compared
  • 16differ
  • 8identical
  • 4known for one product only

Key differences

The CyberPower PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA has 0.7 kVA more output power capacity than the CyberPower CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (2.2 kVA vs 1.5 kVA). The CyberPower PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA has 600 W more output power than the CyberPower CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (1500 W vs 900 W). The CyberPower PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA has 280 J more surge energy rating than the CyberPower CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (1780 J vs 1500 J). Input frequency: 60 Hz on the CyberPower CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, 50/60 Hz on the CyberPower PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA. Replacement battery cartridge: BB - HR1234W on the CyberPower CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, BB - BP9-12 on the CyberPower PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA.

  • Output power capacity
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA:2.2 kVA
  • Output power
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:900 W
    • PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA:1500 W
  • Input frequency
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:60 Hz
    • PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA:50/60 Hz
  • Surge energy rating
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1500 J
    • PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA:1780 J
  • USB 2.0 ports quantity
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:2
    • PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA:1
  • Serial ports quantity
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1
    • PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA:2
  • Typical backup time at full load
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:3 min
    • PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA:4 min
  • Typical backup time at half load
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:11 min
    • PR2200SWRM2U uninterruptible power supply (UPS) 2.2 kVA:12 min

Side by side

Differences highlightedShow differences only (on)
Comparison of CP1500AVRT, PR2200SWRM2U
28 specifications
Features4 differ
UPS topologyKnown for oneLine-InteractiveUnknown — not stated by the source
Output power capacityDiffers1.5 kVA2.2 kVA
Output powerDiffers900 W1500 W
Input frequencyDiffers60 Hz50/60 Hz
Surge energy ratingDiffers1500 J1780 J
Ports & interfaces2 differ
USB 2.0 ports quantityDiffers21
Serial ports quantityDiffers12
Battery4 differ
Typical backup time at full loadDiffers3 min4 min
Typical backup time at half loadDiffers11 min12 min
Battery recharge timeDiffers18 h8 h
Replacement battery cartridgeDiffersBB - HR1234WBB - BP9-12
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Designidentical
Form factorKnown for oneTowerUnknown — not stated by the source
Certificates1 differ
CertificationDiffersUL1778, cUL 107.1, FCC DOC Class BUL1778, cUL, FCC DOC Class B
Weight & dimensions1 differ
WeightDiffers11.3 kg32.2 kg
Other features4 differ
Input connection typeDiffersNEMA 5-15PNEMA 5-20P
Dimensions (WxDxH)Differs101.6 x 336.55 x 247.65 mm438.15 x 400 x 89 mm
Dimensions (W x D x H) (imperial)Differs101.6 x 336.6 x 247.7 mm (4 x 13.2 x 9.75")438.1 x 400.1 x 88.9 mm (17.2 x 15.8 x 3.5")
Weight (imperial)Differs11.3 kg (25 lbs)32.2 kg (71 lbs)
Output connectionsKnown for oneUnknown — not stated by the sourceNEMA 5-15R, NEMA 5-20R

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons