Product comparison · 2 uninterruptible power supplies (upss)

CyberPower CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA vs CyberPower OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA

Add a product
  • 25specifications compared
  • 15differ
  • 10identical
  • 2known for one product only

Key differences

  • Output power capacity
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
  • Output power
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:900 W
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:1320 W
  • Input frequency
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:60 Hz
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:47/63 Hz
  • Surge energy rating
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1500 J
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:1840 J
  • USB 2.0 ports quantity
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:2
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:1
  • Serial ports quantity
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:2
  • Typical backup time at full load
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:3 min
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:5 min
  • Typical backup time at half load
    • CP1500AVRT uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:11 min
    • OR2200LCDRM2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:13 min

Side by side

Differences highlightedShow differences only (off)
Comparison of CP1500AVRT, OR2200LCDRM2U
27 specifications
Features4 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacityDiffers1.5 kVA2 kVA
Output powerDiffers900 W1320 W
Input frequencyDiffers60 Hz47/63 Hz
Surge energy ratingDiffers1500 J1840 J
Response time4 ms4 ms
Audible alarm(s)YesYes
Ports & interfaces2 differ
USB 2.0 ports quantityDiffers21
Serial ports quantityDiffers12
Modem (RJ-11) ports11
Ethernet LAN (RJ-45) ports11
Battery4 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Typical backup time at full loadDiffers3 min5 min
Typical backup time at half loadDiffers11 min13 min
Battery recharge timeDiffers18 h8 h
Replacement battery cartridgeDiffersBB - HR1234WBB - BP9-12
Designidentical
Form factorKnown for oneTowerUnknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Certificatesidentical
CertificationUL1778, cUL 107.1, FCC DOC Class BUL1778, cUL 107.1, FCC DOC Class B
Weight & dimensions1 differ
WeightDiffers11.3 kg25.9 kg
Other features4 differ
Input connection typeDiffersNEMA 5-15PNEMA 5-20P
Dimensions (WxDxH)Differs101.6 x 336.55 x 247.65 mm438.15 x 400 x 89 mm
Operating temperature (T-T)32 - 95 °F32 - 95 °F
Dimensions (W x D x H) (imperial)Differs101.6 x 336.6 x 247.7 mm (4 x 13.2 x 9.75")438.1 x 400.1 x 88.9 mm (17.2 x 15.8 x 3.5")
Weight (imperial)Differs11.3 kg (25 lbs)25.9 kg (57 lbs)
Output connectionsKnown for oneUnknown — not stated by the sourceNEMA 5-20R

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons