Product comparison · 2 uninterruptible power supplies (upss)

CyberPower BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA vs CyberPower PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA

Add a product
  • 43specifications compared
  • 31differ
  • 12identical
  • 30known for one product only

Key differences

  • Output power capacity
    • BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:0.65 kVA
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:3 kVA
  • Output power
    • BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:390 W
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:3000 W
  • Waveform
    • BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:Simulated sine
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:Pure sine
  • Input operation voltage (min)
    • BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:167 V
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:159 V
  • Input operation voltage (max)
    • BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:295 V
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:288 V
  • Maximum current
    • BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:2.83 A
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:16 A
  • Surge energy rating
    • BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:150 J
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:2430 J
  • Power protection features
    • BU650E uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:Overload, Surge protection
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:Overload, Short circuit

Side by side

Differences highlightedShow differences only (off)
Comparison of BU650E, PR3000ERTXL2U
73 specifications
Features9 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacityDiffers0.65 kVA3 kVA
Output powerDiffers390 W3000 W
WaveformDiffersSimulated sinePure sine
Input operation voltage (min)Differs167 V159 V
Input operation voltage (max)Differs295 V288 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source220 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output frequency50/60 Hz50/60 Hz
Automatic Voltage Regulation (AVR)YesYes
Maximum currentDiffers2.83 A16 A
Surge energy ratingDiffers150 J2430 J
Transfer time (Line Mode to Battery Mode)Known for oneUnknown — not stated by the source4 ms
Response time4 ms4 ms
Number of input phasesKnown for oneUnknown — not stated by the source1
Power factorKnown for oneUnknown — not stated by the source1
Power Factor Correction (PFC) typeKnown for oneUnknown — not stated by the sourceActive
EMI/RFI noise filteringYesYes
Surge protectionYesYes
Power protection featuresDiffersOverload, Surge protectionOverload, Short circuit
Audible alarm(s)YesYes
Web-based managementKnown for oneUnknown — not stated by the sourceYes
Audible alarm modesDiffersLow battery alarm, Fault, Overload alarm, Alarm when on batteryAlarm when on battery, Low battery alarm, Overload alarm
Management protocolsKnown for oneUnknown — not stated by the sourceSNMP/HTTP
Socket circuit breakerKnown for oneUnknown — not stated by the sourceYes
Heat dissipationKnown for one36.8 BTU/hUnknown — not stated by the source
Noise levelKnown for one40 dBUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersType IC13 coupler, C19 coupler
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
AC outlets quantityDiffers3 AC outlet(s)8 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Cabling technologyKnown for oneUnknown — not stated by the source10/100/1000Base-T(X)
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Number of outlets (Protection)Known for one3Unknown — not stated by the source
Battery1 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Number of batteries supportedKnown for oneUnknown — not stated by the source4
Typical backup time at full loadKnown for oneUnknown — not stated by the source1.7 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source7.1 min
Battery recharge timeDiffers8 h3 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRBP0129
Design4 differ
Form factorDiffersCompactRackmount/Tower
Product colourBlackBlack
Housing materialDiffersPlasticMetal
Rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthDiffers1.2 m2.4 m
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsDiffersYesError, Operation
Operational conditions4 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-20 - 50 °C-15 - 45 °C
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Storage relative humidity (H-H)Differs0 - 90%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitudeDiffers0 - 3000 m0 - 15000 m
Certificates2 differ
Compliance certificatesDiffersCE, RCM, RoHSRoHS
CertificationDiffersCE , RCMCE , FCC Class A , UL , CISPR 22 Class A , IEC62040-2 , RCM , VCCI , EN 61000-3-2
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Weight & dimensions4 differ
WidthDiffers158 mm433 mm
DepthDiffers240 mm500 mm
HeightDiffers91.5 mm86.5 mm
WeightDiffers4.1 kg32.8 kg
Packaging data4 differ
Package widthDiffers118 mm560 mm
Package depthDiffers281 mm620 mm
Package heightDiffers225 mm275 mm
Package weightDiffers4.23 kg41 kg
Package volumeKnown for oneUnknown — not stated by the source40800 cm³
Logistics data1 differ
Harmonized System (HS) codeDiffers850780008504408590
Country of originKnown for oneUnknown — not stated by the sourceChina
Other featuresidentical
BypassKnown for oneUnknown — not stated by the sourceGreenPower UPS

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons