Product comparison · 2 uninterruptible power supplies (upss)

CyberPower BRG1500AVRLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA vs CyberPower OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA

Add a product
  • 28specifications compared
  • 18differ
  • 10identical
  • 31known for one product only

Key differences

  • UPS topology
    • BRG1500AVRLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Line-Interactive
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:Double-conversion (Online)
  • Output power capacity
    • BRG1500AVRLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:1 kVA
  • Output power
    • BRG1500AVRLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:900 W
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:800 W
  • Input frequency
    • BRG1500AVRLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:60 Hz
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:40/70 Hz
  • AC outlet types
    • BRG1500AVRLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:NEMA 5–15R
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:C13 coupler
  • Power plug
    • BRG1500AVRLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:NEMA 5-15P
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:C14 coupler
  • AC outlets quantity
    • BRG1500AVRLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:12 AC outlet(s)
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:6 AC outlet(s)
  • Battery capacity
    • BRG1500AVRLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:9 Ah
    • OLS1000ERT2U uninterruptible power supply (UPS) Double-conversion (Online) 1 kVA:7 Ah

Side by side

Differences highlightedShow differences only (on)
Comparison of BRG1500AVRLCD, OLS1000ERT2U
59 specifications
Features4 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1.5 kVA1 kVA
Output powerDiffers900 W800 W
Input frequencyDiffers60 Hz40/70 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source208 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
EfficiencyKnown for oneUnknown — not stated by the source95%
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceFax, Modem, Network, Telephone
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm modesKnown for oneUnknown — not stated by the sourceBattery replacement
Auto-restartKnown for oneUnknown — not stated by the sourceYes
Input operation voltage (min)Known for one90 VUnknown — not stated by the source
Input operation voltage (max)Known for one148 VUnknown — not stated by the source
Maximum currentKnown for one2.1 AUnknown — not stated by the source
Surge energy ratingKnown for one1500 JUnknown — not stated by the source
Response timeKnown for one4 msUnknown — not stated by the source
Output power factorKnown for one0.6Unknown — not stated by the source
Ports & interfaces3 differ
AC outlet typesDiffersNEMA 5–15RC13 coupler
Power plugDiffersNEMA 5-15PC14 coupler
AC outlets quantityDiffers12 AC outlet(s)6 AC outlet(s)
Battery5 differ
Battery capacityDiffers9 Ah7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedDiffers23
Typical backup time at full loadDiffers2 min6 min
Typical backup time at half loadDiffers12 min16 min
Battery recharge timeDiffers8 h5 h
Automatic battery testKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneUnknown — not stated by the sourceYes
Hot-swap batteryKnown for oneNoUnknown — not stated by the source
Design2 differ
Form factorDiffersMini TowerRackmount/Tower
Rack capacityKnown for oneUnknown — not stated by the source2U
Cooling typeKnown for oneUnknown — not stated by the sourceActive
LED indicatorsDiffersYesBattery replacement
Weight & dimensions4 differ
WidthDiffers99.1 mm438 mm
DepthDiffers355.6 mm430 mm
HeightDiffers279.4 mm88 mm
WeightDiffers11.3 kg13.2 kg
Packaging dataidentical
Bundled softwareKnown for oneUnknown — not stated by the sourcePowerPanel Business Ed
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 90%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneUL, cUL, FCCUnknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons