Product comparison · 2 uninterruptible power supplies (upss)

CyberPower BR1000ELCD-FR uninterruptible power supply (UPS) Line-Interactive 1 kVA vs CyberPower PR2000ERT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA

Add a product
  • 43specifications compared
  • 26differ
  • 17identical
  • 25known for one product only

Key differences

  • Output power capacity
    • BR1000ELCD-FR uninterruptible power supply (UPS) Line-Interactive 1 kVA:1 kVA
    • PR2000ERT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
  • Output power
    • BR1000ELCD-FR uninterruptible power supply (UPS) Line-Interactive 1 kVA:600 W
    • PR2000ERT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:2000 W
  • Waveform
    • BR1000ELCD-FR uninterruptible power supply (UPS) Line-Interactive 1 kVA:Sine
    • PR2000ERT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:Pure sine
  • Input operation voltage (min)
    • BR1000ELCD-FR uninterruptible power supply (UPS) Line-Interactive 1 kVA:165 V
    • PR2000ERT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:159 V
  • Input operation voltage (max)
    • BR1000ELCD-FR uninterruptible power supply (UPS) Line-Interactive 1 kVA:290 V
    • PR2000ERT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:288 V
  • Surge energy rating
    • BR1000ELCD-FR uninterruptible power supply (UPS) Line-Interactive 1 kVA:125 J
    • PR2000ERT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:2430 J
  • Power protection features
    • BR1000ELCD-FR uninterruptible power supply (UPS) Line-Interactive 1 kVA:Overload
    • PR2000ERT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:Overload, Short circuit
  • AC outlet types
    • BR1000ELCD-FR uninterruptible power supply (UPS) Line-Interactive 1 kVA:Type E
    • PR2000ERT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:C13 coupler

Side by side

Differences highlightedShow differences only (on)
Comparison of BR1000ELCD-FR, PR2000ERT2U
68 specifications
Features8 differ
Output power capacityDiffers1 kVA2 kVA
Output powerDiffers600 W2000 W
WaveformDiffersSinePure sine
Input operation voltage (min)Differs165 V159 V
Input operation voltage (max)Differs290 V288 V
Output operation voltage (min)Known for oneUnknown — not stated by the source220 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Maximum currentKnown for oneUnknown — not stated by the source10 A
Surge energy ratingDiffers125 J2430 J
Number of input phasesKnown for oneUnknown — not stated by the source1
Power factorKnown for oneUnknown — not stated by the source1
Power Factor Correction (PFC) typeKnown for oneUnknown — not stated by the sourceActive
Noise levelKnown for oneUnknown — not stated by the source52.5 dB
Power protection featuresDiffersOverloadOverload, Short circuit
Audible alarm modesDiffersAlarm when on battery, Fault, Low battery alarm, Overload alarmAlarm when on battery, Low battery alarm, Overload alarm
Surge protection featuresKnown for oneDigital Subscriber Line (DSL), Fax, Modem, Network, TelephoneUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersType EC13 coupler
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
AC outlets quantityDiffers8 AC outlet(s)10 AC outlet(s)
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Modem (RJ-11) portsKnown for one2Unknown — not stated by the source
Battery3 differ
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Typical backup time at full loadDiffers1 min4 min
Typical backup time at half loadDiffers6 min13 min
Battery recharge timeDiffers8 h3 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Cold startKnown for oneYesUnknown — not stated by the source
Design4 differ
Form factorDiffersCompactRackmount/Tower
Housing materialDiffersPlasticMetal
Rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthDiffers1.5 m1.8 m
LED indicatorsDiffersYesError, Operation
Operational conditions4 differ
Storage temperature (T-T)Differs-20 - 50 °C-15 - 45 °C
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Storage relative humidity (H-H)Differs0 - 90%0 - 95%
Non-operating altitudeDiffers0 - 3000 m0 - 15000 m
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Cables includedKnown for oneUnknown — not stated by the sourceSerial, USB cable
Certificates1 differ
CertificationDiffersCECE , FCC Class B , UL , RCM , VCCI
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Weight & dimensions4 differ
WidthDiffers166 mm433 mm
DepthDiffers288 mm412 mm
HeightDiffers118 mm86.5 mm
WeightDiffers6.5 kg25.7 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source560 mm
Package depthKnown for oneUnknown — not stated by the source530 mm
Package heightKnown for oneUnknown — not stated by the source275 mm
Package weightKnown for oneUnknown — not stated by the source32.3 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source8504408590
Country of originKnown for oneUnknown — not stated by the sourceChina

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons