Product comparison · 2 uninterruptible power supplies (upss)

CDP R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac vs NGS FORTRESS2000 uninterruptible power supply (UPS) Standby (Offline) 1.5 kVA

Add a product
  • 17specifications compared
  • 10differ
  • 7identical
  • 40known for one product only

Key differences

  • UPS topology
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:Line-Interactive
    • FORTRESS2000 uninterruptible power supply (UPS) Standby (Offline) 1.5 kVA:Standby (Offline)
  • Output power capacity
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:1 kVA
    • FORTRESS2000 uninterruptible power supply (UPS) Standby (Offline) 1.5 kVA:1.5 kVA
  • Output power
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:500 W
    • FORTRESS2000 uninterruptible power supply (UPS) Standby (Offline) 1.5 kVA:900 W
  • Input operation voltage (max)
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:145 V
    • FORTRESS2000 uninterruptible power supply (UPS) Standby (Offline) 1.5 kVA:230 V
  • Input frequency
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:50/60 Hz
    • FORTRESS2000 uninterruptible power supply (UPS) Standby (Offline) 1.5 kVA:50 Hz
  • Response time
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:4 ms
    • FORTRESS2000 uninterruptible power supply (UPS) Standby (Offline) 1.5 kVA:10 ms
  • Battery capacity
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:9 Ah
    • FORTRESS2000 uninterruptible power supply (UPS) Standby (Offline) 1.5 kVA:8 Ah
  • Number of batteries supported
    • R-UPR1008 1000VA/500W UPS AVR, 8 Outlets, 300 Joules, 120 Vac:1
    • FORTRESS2000 uninterruptible power supply (UPS) Standby (Offline) 1.5 kVA:2

Side by side

Differences highlightedShow differences only (on)
Comparison of R-UPR1008, FORTRESS2000
57 specifications
Features6 differ
UPS topologyDiffersLine-InteractiveStandby (Offline)
Output power capacityDiffers1 kVA1.5 kVA
Output powerDiffers500 W900 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Known for one85 VUnknown — not stated by the source
Input operation voltage (max)Differs145 V230 V
Input frequencyDiffers50/60 Hz50 Hz
Output operation voltage (min)Known for one108 VUnknown — not stated by the source
Output operation voltage (max)Known for one132 VUnknown — not stated by the source
Surge energy ratingKnown for one300 JUnknown — not stated by the source
Response timeDiffers4 ms10 ms
Number of input phasesKnown for one1Unknown — not stated by the source
Number of output phasesKnown for one1Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
EfficiencyKnown for oneUnknown — not stated by the source80%
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload, Short circuit
Ports & interfacesidentical
AC outlet typesKnown for oneNEMA 5–15RUnknown — not stated by the source
AC outlets quantityKnown for one8 AC outlet(s)Unknown — not stated by the source
Number of type F outputsKnown for oneUnknown — not stated by the source3
Battery3 differ
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Battery capacityDiffers9 Ah8 Ah
Number of batteries supportedDiffers12
Typical backup time at full loadDiffers4 min10 min
Typical backup time at half loadKnown for one8 minUnknown — not stated by the source
Battery recharge timeKnown for one4 hUnknown — not stated by the source
Cold startKnown for oneUnknown — not stated by the sourceYes
Designidentical
Form factorKnown for oneTowerUnknown — not stated by the source
Cable lengthKnown for one1 mUnknown — not stated by the source
Display typeKnown for oneUnknown — not stated by the sourceLED
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 95%10 - 90%
Weight & dimensionsidentical
WidthKnown for one195 mmUnknown — not stated by the source
DepthKnown for one355 mmUnknown — not stated by the source
HeightKnown for one138 mmUnknown — not stated by the source
WeightKnown for one5.45 kgUnknown — not stated by the source
Packaging dataidentical
Package weightKnown for one5.9 kgUnknown — not stated by the source
Logistics dataidentical
Master (outer) case net weightKnown for one21.8 kgUnknown — not stated by the source
Pallet gross heightKnown for one185 cmUnknown — not stated by the source
Pallet gross lengthKnown for one115 cmUnknown — not stated by the source
Pallet gross weightKnown for one1151.2 kgUnknown — not stated by the source
Pallet gross widthKnown for one115 cmUnknown — not stated by the source
Master (outer) case widthKnown for one365 mmUnknown — not stated by the source
Master (outer) case lengthKnown for one568 mmUnknown — not stated by the source
Master (outer) case heightKnown for one211 mmUnknown — not stated by the source
Master (outer) case gross weightKnown for one23.6 kgUnknown — not stated by the source
Products per master (outer) caseKnown for one4 pc(s)Unknown — not stated by the source
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the sourceNP
Output voltageKnown for oneUnknown — not stated by the source230 V

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.