Product comparison · 2 uninterruptible power supplies (upss)

APC UPS1500THV uninterruptible power supply (UPS) 1.5 kVA vs CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA

Add a product
  • 9specifications compared
  • 8differ
  • 1identical
  • 23known for one product only

Key differences

The CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA has 1.5 kVA more output power capacity than the APC UPS1500THV uninterruptible power supply (UPS) 1.5 kVA (3 kVA vs 1.5 kVA). The CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA has 1,200 W more output power than the APC UPS1500THV uninterruptible power supply (UPS) 1.5 kVA (2250 W vs 1050 W). The APC UPS1500THV uninterruptible power supply (UPS) 1.5 kVA has 4 min more typical backup time at full load than the CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA (7 min vs 3 min). Input frequency: 47/63 Hz on the APC UPS1500THV uninterruptible power supply (UPS) 1.5 kVA, 50/60 Hz on the CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA. Operating relative humidity (H-H): 8 - 80% on the APC UPS1500THV uninterruptible power supply (UPS) 1.5 kVA, 0 - 95% on the CyberPower PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA.

  • Output power capacity
    • UPS1500THV uninterruptible power supply (UPS) 1.5 kVA:1.5 kVA
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:3 kVA
  • Output power
    • UPS1500THV uninterruptible power supply (UPS) 1.5 kVA:1050 W
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:2250 W
  • Input frequency
    • UPS1500THV uninterruptible power supply (UPS) 1.5 kVA:47/63 Hz
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:50/60 Hz
  • Typical backup time at full load
    • UPS1500THV uninterruptible power supply (UPS) 1.5 kVA:7 min
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:3 min
  • Typical backup time at half load
    • UPS1500THV uninterruptible power supply (UPS) 1.5 kVA:16 min
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:8 min
  • Operating relative humidity (H-H)
    • UPS1500THV uninterruptible power supply (UPS) 1.5 kVA:8 - 80%
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:0 - 95%
  • Weight
    • UPS1500THV uninterruptible power supply (UPS) 1.5 kVA:24.1 kg
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:37.2 kg
  • Dimensions (WxDxH)
    • UPS1500THV uninterruptible power supply (UPS) 1.5 kVA:170 x 434 x 216 mm
    • PR3000LCDRT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:438.15 x 495.3 x 89 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of UPS1500THV, PR3000LCDRT2U
32 specifications
Features3 differ
UPS topologyKnown for oneUnknown — not stated by the sourceLine-Interactive
Output power capacityDiffers1.5 kVA3 kVA
Output powerDiffers1050 W2250 W
Input frequencyDiffers47/63 Hz50/60 Hz
Surge energy ratingKnown for oneUnknown — not stated by the source1874 J
Response timeKnown for oneUnknown — not stated by the source4 ms
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
Serial ports quantityKnown for oneUnknown — not stated by the source2
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Battery2 differ
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Typical backup time at full loadDiffers7 min3 min
Typical backup time at half loadDiffers16 min8 min
Battery recharge timeKnown for oneUnknown — not stated by the source8 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceBB - HR9-12
Operational conditions1 differ
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 45 °C
Operating relative humidity (H-H)Differs8 - 80%0 - 95%
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceUL1778, cUL 107.1, FCC DOC Class B
Weight & dimensions1 differ
WeightDiffers24.1 kg37.2 kg
Other features1 differ
Output connectionsKnown for oneUnknown — not stated by the sourceNEMA 5-20R, NEMA L5-30R
Input connection typeKnown for oneUnknown — not stated by the sourceNEMA L5-30P
Dimensions (WxDxH)Differs170 x 434 x 216 mm438.15 x 495.3 x 89 mm
Operating temperature (T-T)Known for oneUnknown — not stated by the source32 - 95 °F
Dimensions (W x D x H) (imperial)Known for oneUnknown — not stated by the source438.1 x 495.3 x 88.9 mm (17.2 x 19.5 x 3.5")
Weight (imperial)Known for oneUnknown — not stated by the source37.2 kg (82 lbs)
InterfaceKnown for oneUSB/serialUnknown — not stated by the source
Compatible operating systemsKnown for oneMicrosoft Windows NT 4.0/2000/XP Novell NetWare 6.0/Red Hat Linux 7.3Unknown — not stated by the source
Designidentical
Form factorKnown for oneTowerUnknown — not stated by the source
Product colourKnown for oneBlackUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.