Product comparison · 2 uninterruptible power supplies (upss)

APC Symmetra PX 10kVA UPS enclosure vs APC Symmetra RM 4kVA

Add a product
  • 8specifications compared
  • 6differ
  • 2identical
  • 17known for one product only

Key differences

The APC Symmetra PX 10kVA UPS enclosure has 6 kVA more output power capacity than the APC Symmetra RM 4kVA (10 kVA vs 4 kVA). The APC Symmetra PX 10kVA UPS enclosure has 7,200 W more output power than the APC Symmetra RM 4kVA (10000 W vs 2800 W). The APC Symmetra RM 4kVA has 2 h more battery recharge time than the APC Symmetra PX 10kVA UPS enclosure (4 h vs 2 h). Dimensions (WxDxH): 1219 x 902 x 2070 mm on the APC Symmetra PX 10kVA UPS enclosure, 483 x 730 x 445 mm on the APC Symmetra RM 4kVA.

  • Output power capacity
    • Symmetra PX 10kVA UPS enclosure:10 kVA
    • Symmetra RM 4kVA:4 kVA
  • Output power
    • Symmetra PX 10kVA UPS enclosure:10000 W
    • Symmetra RM 4kVA:2800 W
  • Battery recharge time
    • Symmetra PX 10kVA UPS enclosure:2 h
    • Symmetra RM 4kVA:4 h
  • Weight
    • Symmetra PX 10kVA UPS enclosure:662.3 kg
    • Symmetra RM 4kVA:147.3 kg
  • Dimensions (WxDxH)
    • Symmetra PX 10kVA UPS enclosure:1219 x 902 x 2070 mm
    • Symmetra RM 4kVA:483 x 730 x 445 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of Symmetra PX 10kVA UPS enclosure, Symmetra RM 4kVA
25 specifications
Features2 differ
Output power capacityDiffers10 kVA4 kVA
Output powerDiffers10000 W2800 W
Noise levelKnown for one64 dBUnknown — not stated by the source
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Battery1 differ
Typical backup time at full loadKnown for one3.6 minUnknown — not stated by the source
Typical backup time at half loadKnown for one13.8 minUnknown — not stated by the source
Battery recharge timeDiffers2 h4 h
Replacement battery cartridgeKnown for oneSYBT4Unknown — not stated by the source
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Designidentical
Cable lengthKnown for oneUnknown — not stated by the source1.83 m
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions1 differ
WeightDiffers662.3 kg147.3 kg
Other features2 differ
Output connectionsDiffers(1) Hard Wire 5-wire (3PH + N + G) (1) Screw Terminals4x NEMA L5-20R 2x NEMA L6-20R
Dimensions (WxDxH)Differs1219 x 902 x 2070 mm483 x 730 x 445 mm
InterfaceKnown for oneUnknown — not stated by the sourceDB-9 RS-232, RJ-45
Input connection typeKnown for oneUnknown — not stated by the source3-wire (2PH + G), NEMA L6-30P
Nominal input voltageKnown for oneUnknown — not stated by the source208 V
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceCSA, FCC Part 15 Class A, UL 1778

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.