Product comparison · 2 uninterruptible power supplies (upss)

APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep vs Vertiv Liebert S600D

Add a product
  • 27specifications compared
  • 21differ
  • 6identical
  • 30known for one product only

Key differences

The Vertiv Liebert S600D has 12 kVA more output power capacity than the APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep (20 kVA vs 8 kVA). The Vertiv Liebert S600D has 14,400 W more output power than the APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep (20000 W vs 5600 W). The Vertiv Liebert S600D has 160 V more input operation voltage (min) than the APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep (380 V vs 220 V). Waveform: Sine on the APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep, Pure sine on the Vertiv Liebert S600D. Input frequency: 45/65 Hz on the APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep, 50/60 Hz on the Vertiv Liebert S600D.

  • Output power capacity
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:8 kVA
    • Liebert S600D:20 kVA
  • Output power
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:5600 W
    • Liebert S600D:20000 W
  • Waveform
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:Sine
    • Liebert S600D:Pure sine
  • Input operation voltage (min)
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:220 V
    • Liebert S600D:380 V
  • Input operation voltage (max)
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:230 V
    • Liebert S600D:415 V
  • Input frequency
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:45/65 Hz
    • Liebert S600D:50/60 Hz
  • Output operation voltage (max)
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:230 V
    • Liebert S600D:240 V
  • Output frequency
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:47/63 Hz
    • Liebert S600D:40/70 Hz

Side by side

Differences highlightedShow differences only (off)
Comparison of SYA8K8IX798XB, Liebert S600D
57 specifications
Features11 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers8 kVA20 kVA
Output powerDiffers5600 W20000 W
WaveformDiffersSinePure sine
Input operation voltage (min)Differs220 V380 V
Input operation voltage (max)Differs230 V415 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)220 V220 V
Output operation voltage (max)Differs230 V240 V
Output frequencyDiffers47/63 Hz40/70 Hz
Output frequency regulationKnown for oneUnknown — not stated by the source0.1 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Number of input phasesKnown for oneUnknown — not stated by the source3
Number of output phasesKnown for oneUnknown — not stated by the source1
EfficiencyDiffers90%91%
Efficiency (On-line mode)Known for oneUnknown — not stated by the source91%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source94%
Power factorKnown for oneUnknown — not stated by the source0.9
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source0.9
Crest factorDiffers5:13:1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Noise levelDiffers62 dB65 dB
Heat dissipationKnown for one3485 BTU/hUnknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one7%Unknown — not stated by the source
Battery1 differ
Battery technologyDiffersLead-AcidSealed Lead Acid (VRLA)
Charging currentKnown for oneUnknown — not stated by the source13 A
Number of batteries supportedKnown for one4Unknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Design1 differ
Form factorDiffersTowerRackmount/Tower
Product colourBlackBlack
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Display typeLCDLCD
BacklightKnown for oneUnknown — not stated by the sourceYes
Backlight colourKnown for oneUnknown — not stated by the sourceBlue
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Operational conditions4 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Differs-15 - 45 °C-40 - 70 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeDiffers0 - 3048 m0 - 3000 m
Non-operating altitudeDiffers0 - 4572 m0 - 3000 m
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Technical detailsidentical
Dispose of contents/container to (P501)Known for oneUnknown — not stated by the sourceAccording to local regulations
Weight & dimensions4 differ
WidthDiffers483 mm335 mm
DepthDiffers726 mm650 mm
HeightDiffers671 mm1300 mm
WeightDiffers143.8 kg175 kg
Ports & interfacesidentical
AC outlet typesKnown for oneHard Wire 3-wire (1PH + N + G)Unknown — not stated by the source
Power plugKnown for oneHardwireUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one997 mmUnknown — not stated by the source
Package depthKnown for one599 mmUnknown — not stated by the source
Package heightKnown for one914 mmUnknown — not stated by the source
Package weightKnown for one229.6 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.