Product comparison · 2 uninterruptible power supplies (upss)

APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep vs CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA

Add a product
  • 25specifications compared
  • 22differ
  • 3identical
  • 40known for one product only

Key differences

The APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep has 5.8 kVA more output power capacity than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (8 kVA vs 2.2 kVA). The APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep has 3,400 W more output power than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (5600 W vs 2200 W). The APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep has 110 V more input operation voltage (min) than the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA (220 V vs 110 V). Waveform: Sine on the APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep, Pure sine on the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA. Input frequency: 45/65 Hz on the APC Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep, 50/60 Hz on the CyberPower Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA.

  • Output power capacity
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:8 kVA
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2.2 kVA
  • Output power
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:5600 W
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:2200 W
  • Waveform
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:Sine
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:Pure sine
  • Input operation voltage (min)
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:220 V
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:110 V
  • Input operation voltage (max)
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:230 V
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:300 V
  • Input frequency
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:45/65 Hz
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:50/60 Hz
  • Output operation voltage (min)
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:220 V
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:200 V
  • Output operation voltage (max)
    • Symmetra LX 8kVA with Batteries and NMC Removed for US State Dep:230 V
    • Online S Series OLS2K2ERT2UH uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA:240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of SYA8K8IX798XB, OLS2K2ERT2UH
65 specifications
Features10 differ
Output power capacityDiffers8 kVA2.2 kVA
Output powerDiffers5600 W2200 W
WaveformDiffersSinePure sine
Input operation voltage (min)Differs220 V110 V
Input operation voltage (max)Differs230 V300 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Differs220 V200 V
Output operation voltage (max)Differs230 V240 V
Output frequencyDiffers47/63 Hz50/60 Hz
Maximum currentKnown for oneUnknown — not stated by the source10.39 A
Surge energy ratingKnown for oneUnknown — not stated by the source1065 J
Heat dissipationDiffers3485 BTU/h564 BTU/h
Number of input phasesKnown for oneUnknown — not stated by the source1
Efficiency (ECO mode)Known for oneUnknown — not stated by the source98%
Power factorKnown for oneUnknown — not stated by the source1
Input power factorKnown for oneUnknown — not stated by the source0.99
ECO modeKnown for oneUnknown — not stated by the sourceYes
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Audible alarm modesKnown for oneUnknown — not stated by the sourceAlarm when on battery, Low battery alarm, Overload alarm, Battery replacement, Fault
EfficiencyKnown for one90%Unknown — not stated by the source
Crest factorKnown for one5:1Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one7%Unknown — not stated by the source
Noise levelKnown for one62 dBUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersHard Wire 3-wire (1PH + N + G)C13 coupler
AC outlets quantityKnown for oneUnknown — not stated by the source6 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
RS-232 portsKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Power plugKnown for oneHardwireUnknown — not stated by the source
Battery1 differ
Battery voltageKnown for oneUnknown — not stated by the source72 V
Typical backup time at full loadKnown for oneUnknown — not stated by the source4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source12 min
Battery recharge timeDiffers3 h4 h
Charging currentKnown for oneUnknown — not stated by the source8 A
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRBP0161
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Number of batteries supportedKnown for one4Unknown — not stated by the source
Battery life (max)Known for one5 year(s)Unknown — not stated by the source
Design1 differ
Form factorDiffersTowerRackmount/Tower
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Cable lengthKnown for oneUnknown — not stated by the source1.5 m
Control typeKnown for oneUnknown — not stated by the sourceButtons
Operational conditions6 differ
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Differs-15 - 45 °C-20 - 50 °C
Operating relative humidity (H-H)Differs0 - 95%20 - 90%
Storage relative humidity (H-H)Differs0 - 95%10 - 90%
Operating altitudeDiffers0 - 3048 m0 - 1500 m
Non-operating altitudeDiffers0 - 4572 m0 - 1500 m
Weight & dimensions3 differ
WidthDiffers483 mm540 mm
DepthDiffers726 mm730 mm
HeightDiffers671 mm230 mm
WeightKnown for one143.8 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one997 mmUnknown — not stated by the source
Package depthKnown for one599 mmUnknown — not stated by the source
Package heightKnown for one914 mmUnknown — not stated by the source
Package weightKnown for one229.6 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons