Product comparison · 2 uninterruptible power supplies (upss)

APC Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries vs Fujitsu PY Online UPS 10kVA / 10kW R/T (6U)

Add a product
  • 17specifications compared
  • 13differ
  • 4identical
  • 34known for one product only

Key differences

The APC Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries has 150 kVA more output power capacity than the Fujitsu PY Online UPS 10kVA / 10kW R/T (6U) (160 kVA vs 10 kVA). The APC Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries has 150,000 W more output power than the Fujitsu PY Online UPS 10kVA / 10kW R/T (6U) (160000 W vs 10000 W). The APC Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries has 120 V more input operation voltage (min) than the Fujitsu PY Online UPS 10kVA / 10kW R/T (6U) (340 V vs 220 V). Input frequency: 40/70 Hz on the APC Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries, 50/60 Hz on the Fujitsu PY Online UPS 10kVA / 10kW R/T (6U). AC outlet types: Hard Wire 5-wire (3PH + N + G) on the APC Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries, C13 coupler, C19 coupler on the Fujitsu PY Online UPS 10kVA / 10kW R/T (6U).

  • Output power capacity
    • Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries:160 kVA
    • PY Online UPS 10kVA / 10kW R/T (6U):10 kVA
  • Output power
    • Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries:160000 W
    • PY Online UPS 10kVA / 10kW R/T (6U):10000 W
  • Input operation voltage (min)
    • Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries:340 V
    • PY Online UPS 10kVA / 10kW R/T (6U):220 V
  • Input operation voltage (max)
    • Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries:477 V
    • PY Online UPS 10kVA / 10kW R/T (6U):415 V
  • Input frequency
    • Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries:40/70 Hz
    • PY Online UPS 10kVA / 10kW R/T (6U):50/60 Hz
  • Output operation voltage (max)
    • Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries:415 V
    • PY Online UPS 10kVA / 10kW R/T (6U):230 V
  • Form factor
    • Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries:Tower
    • PY Online UPS 10kVA / 10kW R/T (6U):Rackmount/Tower
  • Rack capacity
    • Symmetra PX 64kW Scalable to 160kW, without Bypass, Distribution, or Batteries:42U
    • PY Online UPS 10kVA / 10kW R/T (6U):3U

Side by side

Differences highlightedShow differences only (off)
Comparison of SY64K160H-NB, PY Online UPS 10kVA / 10kW R/T (6U)
51 specifications
Features6 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers160 kVA10 kVA
Output powerDiffers160000 W10000 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs340 V220 V
Input operation voltage (max)Differs477 V415 V
Input frequencyDiffers40/70 Hz50/60 Hz
Output operation voltage (min)230 V230 V
Output operation voltage (max)Differs415 V230 V
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Output frequency regulationKnown for one+/- 3 HzUnknown — not stated by the source
Maximum currentKnown for one197 AUnknown — not stated by the source
Number of output phasesKnown for one3Unknown — not stated by the source
EfficiencyKnown for one95%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Noise levelKnown for one63 dBUnknown — not stated by the source
Power protection featuresKnown for oneOverload, Short circuitUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarmUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersHard Wire 5-wire (3PH + N + G)C13 coupler, C19 coupler
RS-232 portsKnown for one1Unknown — not stated by the source
SmartSlotKnown for oneYesUnknown — not stated by the source
AC outlets quantityKnown for oneUnknown — not stated by the source10 AC outlet(s)
Design2 differ
Form factorDiffersTowerRackmount/Tower
Product colourBlackBlack
Rack capacityDiffers42U3U
Display typeLCDLCD
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 1000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneEN 50091-1, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, ISO 14001, ISO 9001, VFI-SS-111Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers600 mm432 mm
DepthDiffers1070 mm715 mm
HeightDiffers1991 mm263 mm
WeightDiffers439 kg112 kg
Packaging dataidentical
Package widthKnown for one848 mmUnknown — not stated by the source
Package depthKnown for one1210 mmUnknown — not stated by the source
Package heightKnown for one2140 mmUnknown — not stated by the source
Package weightKnown for one484 kgUnknown — not stated by the source
Batteryidentical
Typical backup time at full loadKnown for oneUnknown — not stated by the source3.8 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source11.5 min
Other featuresidentical
Number of phasesKnown for oneUnknown — not stated by the source2

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.