Product comparison · 2 uninterruptible power supplies (upss)

APC Symmetra PX 160kW, without Bypass, Distribution, or Batteries vs CyberPower AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA

Add a product
  • 21specifications compared
  • 17differ
  • 4identical
  • 44known for one product only

Key differences

The APC Symmetra PX 160kW, without Bypass, Distribution, or Batteries has 159.1 kVA more output power capacity than the CyberPower AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA (160 kVA vs 0.9 kVA). The APC Symmetra PX 160kW, without Bypass, Distribution, or Batteries has 159,520 W more output power than the CyberPower AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA (160000 W vs 480 W). The APC Symmetra PX 160kW, without Bypass, Distribution, or Batteries has 250 V more input operation voltage (min) than the CyberPower AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA (340 V vs 90 V). UPS topology: Double-conversion (Online) on the APC Symmetra PX 160kW, without Bypass, Distribution, or Batteries, Line-Interactive on the CyberPower AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA. Input frequency: 40/70 Hz on the APC Symmetra PX 160kW, without Bypass, Distribution, or Batteries, 60 Hz on the CyberPower AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA.

  • UPS topology
    • Symmetra PX 160kW, without Bypass, Distribution, or Batteries:Double-conversion (Online)
    • AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:Line-Interactive
  • Output power capacity
    • Symmetra PX 160kW, without Bypass, Distribution, or Batteries:160 kVA
    • AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:0.9 kVA
  • Output power
    • Symmetra PX 160kW, without Bypass, Distribution, or Batteries:160000 W
    • AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:480 W
  • Input operation voltage (min)
    • Symmetra PX 160kW, without Bypass, Distribution, or Batteries:340 V
    • AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:90 V
  • Input operation voltage (max)
    • Symmetra PX 160kW, without Bypass, Distribution, or Batteries:477 V
    • AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:148 V
  • Input frequency
    • Symmetra PX 160kW, without Bypass, Distribution, or Batteries:40/70 Hz
    • AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:60 Hz
  • Output operation voltage (min)
    • Symmetra PX 160kW, without Bypass, Distribution, or Batteries:230 V
    • AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:120 V
  • Output operation voltage (max)
    • Symmetra PX 160kW, without Bypass, Distribution, or Batteries:415 V
    • AVRG900LCD uninterruptible power supply (UPS) Line-Interactive 0.9 kVA:120 V

Side by side

Differences highlightedShow differences only (on)
Comparison of SY160K160H-NB, AVRG900LCD
65 specifications
Features9 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers160 kVA0.9 kVA
Output powerDiffers160000 W480 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs340 V90 V
Input operation voltage (max)Differs477 V148 V
Input frequencyDiffers40/70 Hz60 Hz
Output operation voltage (min)Differs230 V120 V
Output operation voltage (max)Differs415 V120 V
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Output frequency regulationKnown for one+/- 3 HzUnknown — not stated by the source
Maximum currentKnown for one400 AUnknown — not stated by the source
Number of output phasesKnown for one3Unknown — not stated by the source
EfficiencyKnown for one95%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Noise levelKnown for one63 dBUnknown — not stated by the source
Power protection featuresDiffersOverload, Short circuitOverload
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarmUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Surge energy ratingKnown for oneUnknown — not stated by the source1030 J
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
AC outlet typesDiffersHard Wire 5-wire (3PH + N + G)NEMA 5–15R
RS-232 portsKnown for one1Unknown — not stated by the source
SmartSlotKnown for oneYesUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15P
AC outlets quantityKnown for oneUnknown — not stated by the source12 AC outlet(s)
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source3
Batteryidentical
Replacement battery cartridgeKnown for oneSYPBV96K160HUnknown — not stated by the source
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Typical backup time at full loadKnown for oneUnknown — not stated by the source2 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source10 min
Battery recharge timeKnown for oneUnknown — not stated by the source8 h
Design1 differ
Form factorDiffersTowerCompact
Rack capacityKnown for one42UUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Cable lengthKnown for oneUnknown — not stated by the source1.5 m
Operational conditions2 differ
Storage temperature (T-T)Differs-15 - 40 °C-15 - 45 °C
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeDiffers0 - 1000 m0 - 2000 m
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneEN 50091-1, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, ISO 14001, ISO 9001, VFI-SS-111Unknown — not stated by the source
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS
Weight & dimensions4 differ
WidthDiffers600 mm310 mm
DepthDiffers1070 mm88.9 mm
HeightDiffers1991 mm178 mm
WeightDiffers610 kg6.44 kg
Packaging dataidentical
Package widthKnown for one848 mmUnknown — not stated by the source
Package depthKnown for one1210 mmUnknown — not stated by the source
Package heightKnown for one2140 mmUnknown — not stated by the source
Package weightKnown for one673 kgUnknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL1778 4th, cUL 107.3-05, FCC/DoC Class B

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.