Product comparison · 2 uninterruptible power supplies (upss)

APC Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable vs CyberPower OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA

Add a product
  • 15specifications compared
  • 11differ
  • 4identical
  • 42known for one product only

Key differences

The APC Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable has 499.4 kVA more output power capacity than the CyberPower OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA (500 kVA vs 0.6 kVA). The APC Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable has 499,640 W more output power than the CyberPower OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA (500000 W vs 360 W). The APC Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable has 240 V more input operation voltage (min) than the CyberPower OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA (400 V vs 160 V). Input frequency: 40/70 Hz on the APC Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable, 47/63 Hz on the CyberPower OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA. Form factor: Tower on the APC Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable, Rackmount on the CyberPower OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA.

  • Output power capacity
    • Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable:500 kVA
    • OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA:0.6 kVA
  • Output power
    • Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable:500000 W
    • OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA:360 W
  • Input operation voltage (min)
    • Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable:400 V
    • OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA:160 V
  • Input operation voltage (max)
    • Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable:552 V
    • OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA:265 V
  • Input frequency
    • Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable:40/70 Hz
    • OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA:47/63 Hz
  • Output operation voltage (max)
    • Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable:480 V
    • OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA:230 V
  • Form factor
    • Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable:Tower
    • OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA:Rackmount
  • Width
    • Symmetra PX 125kW Scalable to 500kW without Bypass, Distribution or Batteries-Parallel Capable:1800 mm
    • OR600ELCDRM1U uninterruptible power supply (UPS) 0.6 kVA:430 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of SY125K500D-NB, OR600ELCDRM1U
57 specifications
Features6 differ
UPS topologyKnown for oneDouble-conversion (Online)Unknown — not stated by the source
Output power capacityDiffers500 kVA0.6 kVA
Output powerDiffers500000 W360 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs400 V160 V
Input operation voltage (max)Differs552 V265 V
Input frequencyDiffers40/70 Hz47/63 Hz
Output operation voltage (min)Known for one400 VUnknown — not stated by the source
Output operation voltage (max)Differs480 V230 V
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Response timeKnown for one2 msUnknown — not stated by the source
Number of input phasesKnown for one2Unknown — not stated by the source
Number of output phasesKnown for one3Unknown — not stated by the source
EfficiencyKnown for one96%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Noise levelKnown for one54 dBUnknown — not stated by the source
Power protection featuresKnown for oneOverload, Short circuitUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarmUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlet typesKnown for oneHard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
SmartSlotKnown for oneYesUnknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
AC outlets quantityKnown for oneUnknown — not stated by the source6 AC outlet(s)
Design1 differ
Form factorDiffersTowerRackmount
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Rack capacityKnown for oneUnknown — not stated by the source1U
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-30 - 70 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 1000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneYesUnknown — not stated by the source
Quick installation guideKnown for oneYesUnknown — not stated by the source
Certificatesidentical
CertificationKnown for onecUL Listed, CSA C22.2 No.107.3-05, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, OSHPD, UL 1778, UL 60950-1, UL ListedUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers1800 mm430 mm
DepthDiffers1070 mm235 mm
HeightDiffers1991 mm440 mm
WeightDiffers1136 kg8.1 kg
Packaging dataidentical
Package widthKnown for one1870 mmUnknown — not stated by the source
Package depthKnown for one1270 mmUnknown — not stated by the source
Package heightKnown for one2150 mmUnknown — not stated by the source
Package weightKnown for one1309 kgUnknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Typical backup time at full loadKnown for oneUnknown — not stated by the source4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source12 min
Battery recharge timeKnown for oneUnknown — not stated by the source8 h
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85078000
Other featuresidentical
Overload protectionKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.