Product comparison · 2 uninterruptible power supplies (upss)

APC SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA vs APC Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution

Add a product
  • 17specifications compared
  • 7differ
  • 10identical
  • 5known for one product only

Key differences

The APC Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution has 150 kVA more output power capacity than the APC SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA (250 kVA vs 100 kVA). The APC Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution has 150,000 W more output power than the APC SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA (250000 W vs 100000 W). The APC Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution has 4.5 h more battery recharge time than the APC SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA (8 h vs 3.50 h).

  • Output power capacity
    • SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA:100 kVA
    • Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution:250 kVA
  • Output power
    • SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA:100000 W
    • Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution:250000 W
  • Battery recharge time
    • SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA:3.50 h
    • Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution:8 h
  • Weight
    • SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA:2632.7 kg
    • Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution:4911.8 kg
  • Dimensions (WxDxH)
    • SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA:2350 x 1070 x 1991 mm
    • Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution:3700 x 1070 x 1991 mm
  • Package dimensions (WxDxH)
    • SY100K250DL-PD uninterruptible power supply (UPS) 100 kVA:2990 x 1270 x 2150 mm
    • Symmetra PX 250kW Scalable to 500kW with Left Mounted Maintenance Bypass and Distribution:4860 x 1270 x 2150 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of SY100K250DL-PD, SY250K500DL-PD
22 specifications
Features2 differ
Output power capacityDiffers100 kVA250 kVA
Output powerDiffers100000 W250000 W
Input frequency40/70 Hz40/70 Hz
Emergency Power Off (EPO)YesYes
Battery1 differ
Battery recharge timeDiffers3.50 h8 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Designidentical
Product colourBlackBlack
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 40 °C-15 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 999.9 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Certificates1 differ
CertificationDifferscUL Listed,CE,EN 50091-1,EN/IEC 62040-3,EN/IEC 62040-1-1,FCC Part 15 Class A,UL Listed,VFI-SS-111cUL Listed,CE,EN/IEC 62040-2,EN/IEC 62040-3,EN/IEC 62040-1-1,UL 1778,UL 60950-1,UL Listed
Weight & dimensions1 differ
WeightDiffers2632.7 kg4911.8 kg
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source5517.3 kg
Other features2 differ
Battery typeVRLAVRLA
Output connections1x Hard Wire 4-wire (3PH + G) 1x Hard Wire 5-wire (3PH + N + G)1x Hard Wire 4-wire (3PH + G) 1x Hard Wire 5-wire (3PH + N + G)
Input connection typeHard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)Hard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)
Dimensions (WxDxH)Differs2350 x 1070 x 1991 mm3700 x 1070 x 1991 mm
Package dimensions (WxDxH)Differs2990 x 1270 x 2150 mm4860 x 1270 x 2150 mm
InterfaceKnown for oneSmart-SlotUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.