Product comparison · 2 uninterruptible power supplies (upss)

APC Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable vs APC SY40K100F uninterruptible power supply (UPS) 40 kVA

Add a product
  • 24specifications compared
  • 13differ
  • 11identical
  • 4known for one product only

Key differences

The APC Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable has 60 kVA more output power capacity than the APC SY40K100F uninterruptible power supply (UPS) 40 kVA (100 kVA vs 40 kVA). The APC Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable has 60,000 W more output power than the APC SY40K100F uninterruptible power supply (UPS) 40 kVA (100000 W vs 40000 W). The APC Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable has 3% more efficiency than the APC SY40K100F uninterruptible power supply (UPS) 40 kVA (96% vs 93%). AC outlets quantity: 2 AC outlet(s) on the APC Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable, 1 AC outlet(s) on the APC SY40K100F uninterruptible power supply (UPS) 40 kVA. Interface: Parallel on the APC Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable, SmartSlot on the APC SY40K100F uninterruptible power supply (UPS) 40 kVA.

  • Output power capacity
    • Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable:100 kVA
    • SY40K100F uninterruptible power supply (UPS) 40 kVA:40 kVA
  • Output power
    • Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable:100000 W
    • SY40K100F uninterruptible power supply (UPS) 40 kVA:40000 W
  • Efficiency
    • Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable:96%
    • SY40K100F uninterruptible power supply (UPS) 40 kVA:93%
  • Noise level
    • Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable:54 dB
    • SY40K100F uninterruptible power supply (UPS) 40 kVA:67 dB
  • AC outlets quantity
    • Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable:2 AC outlet(s)
    • SY40K100F uninterruptible power supply (UPS) 40 kVA:1 AC outlet(s)
  • Battery recharge time
    • Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable:3.50 h
    • SY40K100F uninterruptible power supply (UPS) 40 kVA:2 h
  • Width
    • Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable:2350 mm
    • SY40K100F uninterruptible power supply (UPS) 40 kVA:1200 mm
  • Height
    • Symmetra PX 100KW Scalable to 250KW Without Maintenance Bypass or Distribution-Parallel Capable:1991 mm
    • SY40K100F uninterruptible power supply (UPS) 40 kVA:2011 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of SY100K250D, SY40K100F
28 specifications
Features4 differ
Output power capacityDiffers100 kVA40 kVA
Output powerDiffers100000 W40000 W
EfficiencyDiffers96%93%
Noise levelDiffers54 dB67 dB
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
AC outlets quantityDiffers2 AC outlet(s)1 AC outlet(s)
Battery1 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery recharge timeDiffers3.50 h2 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Designidentical
Form factorTowerTower
Product colourBlackBlack
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 40 °C-15 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 999.9 m0 - 999.9 m
Non-operating altitude0 - 15000 m0 - 15000 m
Certificates1 differ
CertificationDifferscUL,CE,EN 50091-1,EN/IEC 62040-3,EN/IEC 62040-1-1,FCC Part 15 Class A,UL,VFI-SS-111CE,EN/IEC 62040-3,FCC Part 15 Class A,ISO 14001,ISO 9001,UL 1778
Weight & dimensions2 differ
WidthDiffers2350 mm1200 mm
Depth1070 mm1070 mm
HeightDiffers1991 mm2011 mm
Other features4 differ
Battery typeVRLAVRLA
InterfaceDiffersParallelSmartSlot
Output connectionsDiffers1x Hard Wire 4-wire (3PH + G) 1x Hard Wire 5-wire (3PH + N + G)1x 3PH + N + G
Input connection typeKnown for oneHard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)Unknown — not stated by the source
Nominal input voltageDiffers400-480 V208 V
Nominal output voltageDiffers400 V120-208 V
Package dimensions (WxDxH)Known for oneUnknown — not stated by the source1696 x 1210 x 2140 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.