Product comparison · 2 uninterruptible power supplies (upss)

APC SUVTR20KG3B5S uninterruptible power supply (UPS) 20 kVA vs Fujitsu APC Online 8kVA R/T

Add a product
  • 4specifications compared
  • 3differ
  • 1identical
  • 30known for one product only

Key differences

The APC SUVTR20KG3B5S uninterruptible power supply (UPS) 20 kVA has 12 kVA more output power capacity than the Fujitsu APC Online 8kVA R/T (20 kVA vs 8 kVA). The APC SUVTR20KG3B5S uninterruptible power supply (UPS) 20 kVA has 9,600 W more output power than the Fujitsu APC Online 8kVA R/T (16000 W vs 6400 W). Certification: cUL Listed,ISO 14001,ISO 9001,UL 1778 on the APC SUVTR20KG3B5S uninterruptible power supply (UPS) 20 kVA, CE, EN, CB on the Fujitsu APC Online 8kVA R/T.

  • Output power capacity
    • SUVTR20KG3B5S uninterruptible power supply (UPS) 20 kVA:20 kVA
    • APC Online 8kVA R/T:8 kVA
  • Output power
    • SUVTR20KG3B5S uninterruptible power supply (UPS) 20 kVA:16000 W
    • APC Online 8kVA R/T:6400 W

Side by side

Differences highlightedShow differences only (on)
Comparison of SUVTR20KG3B5S, APC Online 8kVA R/T
34 specifications
Features2 differ
Output power capacityDiffers20 kVA8 kVA
Output powerDiffers16000 W6400 W
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
UPS topologyKnown for oneUnknown — not stated by the sourceDouble-conversion (Online)
Input operation voltage (min)Known for oneUnknown — not stated by the source220 V
Input operation voltage (max)Known for oneUnknown — not stated by the source415 V
Input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source230 V
Output operation voltage (max)Known for oneUnknown — not stated by the source230 V
Number of input phasesKnown for oneUnknown — not stated by the source3
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Typical backup time at full loadKnown for oneUnknown — not stated by the source6.3 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source17.9 min
Designidentical
Form factorKnown for oneUnknown — not stated by the sourceRackmount/Tower
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-50 - 40 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Certificates1 differ
CertificationDifferscUL Listed,ISO 14001,ISO 9001,UL 1778CE, EN, CB
Weight & dimensionsidentical
WeightKnown for one859.1 kgUnknown — not stated by the source
WidthKnown for oneUnknown — not stated by the source432 mm
DepthKnown for oneUnknown — not stated by the source663 mm
HeightKnown for oneUnknown — not stated by the source263 mm
Other featuresidentical
Battery typeKnown for oneVRLAUnknown — not stated by the source
InterfaceKnown for oneSmart-SlotUnknown — not stated by the source
Output connectionsKnown for one1x Hard Wire 5-wire (3PH + N + G) 5x NEMA L21-20Unknown — not stated by the source
Input connection typeKnown for oneHard Wire 4-wire (3PH + G)Unknown — not stated by the source
Dimensions (WxDxH)Known for one600 x 1075 x 1995 mmUnknown — not stated by the source
Nominal input voltageKnown for one480 VUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler, C19 coupler
AC outlets quantityKnown for oneUnknown — not stated by the source8 AC outlet(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.