Product comparison · 2 uninterruptible power supplies (upss)

APC SURTD3000XLI + WBEXTWAR3YR-SP-04 vs Vertiv GXT3-MT On-Line UPS, 1000VA

Add a product
  • 25specifications compared
  • 17differ
  • 8identical
  • 32known for one product only

Key differences

The APC SURTD3000XLI + WBEXTWAR3YR-SP-04 has 2 kVA more output power capacity than the Vertiv GXT3-MT On-Line UPS, 1000VA (3 kVA vs 1 kVA). The APC SURTD3000XLI + WBEXTWAR3YR-SP-04 has 1,200 W more output power than the Vertiv GXT3-MT On-Line UPS, 1000VA (2100 W vs 900 W). The Vertiv GXT3-MT On-Line UPS, 1000VA has 20 V more input operation voltage (min) than the APC SURTD3000XLI + WBEXTWAR3YR-SP-04 (120 V vs 100 V). AC outlet types: C13 coupler, C19 coupler on the APC SURTD3000XLI + WBEXTWAR3YR-SP-04, NEMA 5–15R on the Vertiv GXT3-MT On-Line UPS, 1000VA. AC outlets quantity: 10 AC outlet(s) on the APC SURTD3000XLI + WBEXTWAR3YR-SP-04, 6 AC outlet(s) on the Vertiv GXT3-MT On-Line UPS, 1000VA.

  • Output power capacity
    • SURTD3000XLI + WBEXTWAR3YR-SP-04:3 kVA
    • GXT3-MT On-Line UPS, 1000VA:1 kVA
  • Output power
    • SURTD3000XLI + WBEXTWAR3YR-SP-04:2100 W
    • GXT3-MT On-Line UPS, 1000VA:900 W
  • Input operation voltage (min)
    • SURTD3000XLI + WBEXTWAR3YR-SP-04:100 V
    • GXT3-MT On-Line UPS, 1000VA:120 V
  • Input operation voltage (max)
    • SURTD3000XLI + WBEXTWAR3YR-SP-04:280 V
    • GXT3-MT On-Line UPS, 1000VA:140 V
  • Output operation voltage (min)
    • SURTD3000XLI + WBEXTWAR3YR-SP-04:220 V
    • GXT3-MT On-Line UPS, 1000VA:110 V
  • Output operation voltage (max)
    • SURTD3000XLI + WBEXTWAR3YR-SP-04:240 V
    • GXT3-MT On-Line UPS, 1000VA:127 V
  • Noise level
    • SURTD3000XLI + WBEXTWAR3YR-SP-04:55 dB
    • GXT3-MT On-Line UPS, 1000VA:43 dB
  • AC outlet types
    • SURTD3000XLI + WBEXTWAR3YR-SP-04:C13 coupler, C19 coupler
    • GXT3-MT On-Line UPS, 1000VA:NEMA 5–15R

Side by side

Differences highlightedShow differences only (off)
Comparison of SURTD3000XLI + WBEXTWAR3YR-SP-04, GXT3-MT On-Line UPS, 1000VA
57 specifications
Features7 differ
UPS topologyKnown for oneDouble-conversion (Online)Unknown — not stated by the source
Output power capacityDiffers3 kVA1 kVA
Output powerDiffers2100 W900 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs100 V120 V
Input operation voltage (max)Differs280 V140 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)Differs220 V110 V
Output operation voltage (max)Differs240 V127 V
Output frequency regulationKnown for one47/63 HzUnknown — not stated by the source
Surge energy ratingKnown for one555 JUnknown — not stated by the source
EfficiencyKnown for one91.6%Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Noise levelDiffers55 dB43 dB
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Maximum currentKnown for oneUnknown — not stated by the source8.3 A
Power factorKnown for oneUnknown — not stated by the source0.9
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Ports & interfaces2 differ
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5–15R
AC outlets quantityDiffers10 AC outlet(s)6 AC outlet(s)
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Battery2 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Number of batteries supportedKnown for one2Unknown — not stated by the source
Typical backup time at full loadDiffers14.2 min5 min
Typical backup time at half loadKnown for one34.3 minUnknown — not stated by the source
Battery recharge timeDiffers2.5 h3 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmount/TowerTower
Product colourBlackBlack
Rack capacityKnown for one3UUnknown — not stated by the source
Cable lengthKnown for one2.44 mUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Differs-15 - 45 °C-15 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneBSMI, C-tick, CE, CSA, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, JEON, UL 1778, VCCI, VDEUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers130 mm430 mm
DepthDiffers660 mm497 mm
HeightDiffers432 mm85 mm
WeightDiffers54.5 kg16.8 kg
Packaging dataidentical
Package widthKnown for one603 mmUnknown — not stated by the source
Package depthKnown for one980 mmUnknown — not stated by the source
Package heightKnown for one347 mmUnknown — not stated by the source
Package weightKnown for one63.6 kgUnknown — not stated by the source
Other featuresidentical
Number of phases11

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.