Product comparison · 2 uninterruptible power supplies (upss)

APC SURTD3000XLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA vs CyberPower PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA

Add a product
  • 36specifications compared
  • 23differ
  • 13identical
  • 33known for one product only

Key differences

  • UPS topology
    • SURTD3000XLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Double-conversion (Online)
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:Line-Interactive
  • Output power capacity
    • SURTD3000XLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:0.5 kVA
  • Output power
    • SURTD3000XLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2100 W
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:400 W
  • Input operation voltage (min)
    • SURTD3000XLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:100 V
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:80 V
  • Input operation voltage (max)
    • SURTD3000XLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:280 V
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:150 V
  • Input frequency
    • SURTD3000XLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:45/65 Hz
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:57/63 Hz
  • Output operation voltage (max)
    • SURTD3000XLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:120 V
  • Surge energy rating
    • SURTD3000XLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:555 J
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:1030 J

Side by side

Differences highlightedShow differences only (off)
Comparison of SURTD3000XLI-BNDL, PR500LCDRT1U
69 specifications
Features8 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers3 kVA0.5 kVA
Output powerDiffers2100 W400 W
WaveformSineSine
Input operation voltage (min)Differs100 V80 V
Input operation voltage (max)Differs280 V150 V
Input frequencyDiffers45/65 Hz57/63 Hz
Output operation voltage (min)Known for one220 VUnknown — not stated by the source
Output operation voltage (max)Differs240 V120 V
Surge energy ratingDiffers555 J1030 J
EfficiencyKnown for one91.6%Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Noise levelKnown for one55 dBUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Audible alarm(s)YesYes
Auto-restartKnown for oneYesUnknown — not stated by the source
Output frequencyKnown for oneUnknown — not stated by the source60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Power factorKnown for oneUnknown — not stated by the source0.8
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Ports & interfaces2 differ
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5–15R
AC outlets quantityDiffers10 AC outlet(s)7 AC outlet(s)
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
Serial ports quantity11
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15P
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Battery1 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Number of battery cellsKnown for one2Unknown — not stated by the source
Battery recharge timeDiffers2.50 h6 h
Hot-swap batteryYesYes
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Number of batteries supportedKnown for oneUnknown — not stated by the source2
Typical backup time at full loadKnown for oneUnknown — not stated by the source3 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source12 min
Design4 differ
Form factorDiffersRackmountRackmount/Tower
Product colourBlackBlack
Rack capacityDiffers3U1U
Cable lengthDiffers2.44 m3 m
Display typeDiffersLEDLCD
LED indicatorsYesYes
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 45 °C-15 - 45 °C
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneBSMI, C-tick, CE, CSA, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, JEON, UL 1778, VCCI, VDE REACHUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers130 mm438.1 mm
DepthDiffers660 mm241.3 mm
HeightDiffers432 mm44.5 mm
WeightDiffers54.5 kg8.98 kg
Packaging data4 differ
Package widthDiffers603 mm528.3 mm
Package depthDiffers980 mm335.3 mm
Package heightDiffers347 mm157.5 mm
Package weightDiffers63.6 kg11.5 kg
Other featuresidentical
Battery typeKnown for oneRBC44Unknown — not stated by the source
Output connectionsKnown for one8 x C13 & 2 x C19Unknown — not stated by the source
Input connection typeKnown for oneBS1363A & IEC-320 C20 & Schuko CEE 7/EU1-16PUnknown — not stated by the source
Nominal input voltageKnown for one230 VUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageKnown for oneUnknown — not stated by the source120 V
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons