Product comparison · 2 uninterruptible power supplies (upss)

APC SURTA3000XL-BR uninterruptible power supply (UPS) 3 kVA vs CyberPower OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA

Add a product
  • 30specifications compared
  • 21differ
  • 9identical
  • 29known for one product only

Key differences

  • Output power capacity
    • SURTA3000XL-BR uninterruptible power supply (UPS) 3 kVA:3 kVA
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:1.5 kVA
  • Output power
    • SURTA3000XL-BR uninterruptible power supply (UPS) 3 kVA:2100 W
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:1350 W
  • Input operation voltage (min)
    • SURTA3000XL-BR uninterruptible power supply (UPS) 3 kVA:90 V
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:100 V
  • Input operation voltage (max)
    • SURTA3000XL-BR uninterruptible power supply (UPS) 3 kVA:150 V
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:125 V
  • Input frequency
    • SURTA3000XL-BR uninterruptible power supply (UPS) 3 kVA:50/60 Hz
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:40/70 Hz
  • Output operation voltage (max)
    • SURTA3000XL-BR uninterruptible power supply (UPS) 3 kVA:120 V
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:125 V
  • Noise level
    • SURTA3000XL-BR uninterruptible power supply (UPS) 3 kVA:55 dB
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:50 dB
  • Power plug
    • SURTA3000XL-BR uninterruptible power supply (UPS) 3 kVA:NEMA 5-30P
    • OL1500RTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 1.5 kVA:NEMA 1-15P

Side by side

Differences highlightedShow differences only (on)
Comparison of SURTA3000XL-BR, OL1500RTXL2U
59 specifications
Features7 differ
UPS topologyKnown for oneUnknown — not stated by the sourceDouble-conversion (Online)
Output power capacityDiffers3 kVA1.5 kVA
Output powerDiffers2100 W1350 W
Input operation voltage (min)Differs90 V100 V
Input operation voltage (max)Differs150 V125 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source100 V
Output operation voltage (max)Differs120 V125 V
Response timeKnown for oneUnknown — not stated by the source0 ms
EfficiencyKnown for oneUnknown — not stated by the source93%
Power factorKnown for oneUnknown — not stated by the source0.9
Noise levelDiffers55 dB50 dB
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceNetwork
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Surge energy ratingKnown for one480 JUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesKnown for oneUnknown — not stated by the sourceNEMA 5–15R
Power plugDiffersNEMA 5-30PNEMA 1-15P
AC outlets quantityDiffers4 AC outlet(s)8 AC outlet(s)
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
RS-232 portsKnown for one1Unknown — not stated by the source
Battery1 differ
Number of battery cellsKnown for oneUnknown — not stated by the source3
Typical backup time at full loadKnown for oneUnknown — not stated by the source3 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source9 min
Battery recharge timeDiffers2.5 h5 h
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRB1290X3
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Design3 differ
Form factorDiffersRackmountRackmount/Tower
Housing materialKnown for oneUnknown — not stated by the sourceSteel
Rack capacityDiffers3U2U
Cable lengthDiffers2.44 m3.05 m
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Certificates1 differ
CertificationDiffersIEEE, ULUL1778, CSA C22.2 NO.107.3-05, FCC DOC A
Weight & dimensions4 differ
WidthDiffers130 mm433 mm
DepthDiffers660 mm430 mm
HeightDiffers432 mm88 mm
WeightDiffers54.5 kg18 kg
Packaging data1 differ
Package weightDiffers63.6 kg24.4 kg
Other features1 differ
Battery typeKnown for oneUnknown — not stated by the source12V/9Ah
Package dimensions (WxDxH)Differs603 x 980 x 347 mm550 x 590 x 240 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons