Product comparison · 2 uninterruptible power supplies (upss)

APC SURT2000XLI+SURTRK uninterruptible power supply (UPS) 2 kVA vs CyberPower PR3000LCD uninterruptible power supply (UPS) 3 kVA

Add a product
  • 27specifications compared
  • 20differ
  • 7identical
  • 34known for one product only

Key differences

  • Output power capacity
    • SURT2000XLI+SURTRK uninterruptible power supply (UPS) 2 kVA:2 kVA
    • PR3000LCD uninterruptible power supply (UPS) 3 kVA:3 kVA
  • Output power
    • SURT2000XLI+SURTRK uninterruptible power supply (UPS) 2 kVA:1400 W
    • PR3000LCD uninterruptible power supply (UPS) 3 kVA:2700 W
  • Input operation voltage (min)
    • SURT2000XLI+SURTRK uninterruptible power supply (UPS) 2 kVA:100 V
    • PR3000LCD uninterruptible power supply (UPS) 3 kVA:75 V
  • Input operation voltage (max)
    • SURT2000XLI+SURTRK uninterruptible power supply (UPS) 2 kVA:280 V
    • PR3000LCD uninterruptible power supply (UPS) 3 kVA:154 V
  • Input frequency
    • SURT2000XLI+SURTRK uninterruptible power supply (UPS) 2 kVA:50/60 Hz
    • PR3000LCD uninterruptible power supply (UPS) 3 kVA:47/63 Hz
  • Surge energy rating
    • SURT2000XLI+SURTRK uninterruptible power supply (UPS) 2 kVA:420 J
    • PR3000LCD uninterruptible power supply (UPS) 3 kVA:1030 J
  • EMI/RFI noise filtering
    • SURT2000XLI+SURTRK uninterruptible power supply (UPS) 2 kVA:50 dB
    • PR3000LCD uninterruptible power supply (UPS) 3 kVA:Yes
  • AC outlet types
    • SURT2000XLI+SURTRK uninterruptible power supply (UPS) 2 kVA:C13 coupler
    • PR3000LCD uninterruptible power supply (UPS) 3 kVA:NEMA 5–15R, NEMA 5–20R

Side by side

Differences highlightedShow differences only (on)
Comparison of SURT2000XLI+SURTRK, PR3000LCD
61 specifications
Features7 differ
Output power capacityDiffers2 kVA3 kVA
Output powerDiffers1400 W2700 W
Input operation voltage (min)Differs100 V75 V
Input operation voltage (max)Differs280 V154 V
Input frequencyDiffers50/60 Hz47/63 Hz
Output operation voltage (min)Known for one220 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Surge energy ratingDiffers420 J1030 J
Number of input phasesKnown for one8Unknown — not stated by the source
Number of output phasesKnown for one1Unknown — not stated by the source
EfficiencyKnown for one90%Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
EMI/RFI noise filteringDiffers50 dBYes
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
WaveformKnown for oneUnknown — not stated by the sourceSine
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source5%
Ports & interfaces3 differ
AC outlet typesDiffersC13 couplerNEMA 5–15R, NEMA 5–20R
Power plugDiffersC20 couplerNEMA L5-30P
AC outlets quantityDiffers8 AC outlet(s)10 AC outlet(s)
Number of output IEC jumpersKnown for one3Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Battery3 differ
Typical backup time at full loadDiffers1000 min6 min
Typical backup time at half loadDiffers2 min17 min
Battery recharge timeDiffers4 h8 h
Battery capacityKnown for oneUnknown — not stated by the source17 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Design2 differ
Form factorDiffersRackmountMini Tower
Rack capacityKnown for one2UUnknown — not stated by the source
LED indicatorsDiffersPower, StatusYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Display typeKnown for oneUnknown — not stated by the sourceLCD
Operational conditions1 differ
Storage temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Operating relative humidity (H-H)Differs0 - 95%0 - 90%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceUL1778, cUL CSA C22.2 No. 107.3, FCC DOC
Weight & dimensions4 differ
WidthDiffers85 mm195.6 mm
DepthDiffers483 mm513.1 mm
HeightDiffers432 mm431.8 mm
WeightDiffers25 kg56.2 kg
Packaging dataidentical
Package weightKnown for one29.8 kgUnknown — not stated by the source
Other featuresidentical
Number of phasesKnown for one9Unknown — not stated by the source
Package dimensions (WxDxH)Known for one630 x 594 x 286 mmUnknown — not stated by the source
Nominal input voltageKnown for oneUnknown — not stated by the source120 V
Nominal output voltageKnown for oneUnknown — not stated by the source120 V
Output connection typeKnown for oneUnknown — not stated by the source8 x NEMA 5-15R & 2 x NEMA 5-20R
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.