Product comparison · 2 uninterruptible power supplies (upss)

APC SURT1000RMXLI + WBEXTWAR3YR-SP-03 vs APC SURT6000RMXLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA

Add a product
  • 46specifications compared
  • 21differ
  • 25identical
  • 14known for one product only

Key differences

  • Output power capacity
    • SURT1000RMXLI + WBEXTWAR3YR-SP-03:1 kVA
    • SURT6000RMXLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:6 kVA
  • Output power
    • SURT1000RMXLI + WBEXTWAR3YR-SP-03:700 W
    • SURT6000RMXLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:4200 W
  • Input frequency
    • SURT1000RMXLI + WBEXTWAR3YR-SP-03:50/60 Hz
    • SURT6000RMXLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:45/65 Hz
  • Surge energy rating
    • SURT1000RMXLI + WBEXTWAR3YR-SP-03:420 J
    • SURT6000RMXLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:555 J
  • Efficiency
    • SURT1000RMXLI + WBEXTWAR3YR-SP-03:89.1%
    • SURT6000RMXLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:92%
  • Noise level
    • SURT1000RMXLI + WBEXTWAR3YR-SP-03:50 dB
    • SURT6000RMXLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:55 dB
  • AC outlet types
    • SURT1000RMXLI + WBEXTWAR3YR-SP-03:C13 coupler
    • SURT6000RMXLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:C13 coupler, C19 coupler
  • Power plug
    • SURT1000RMXLI + WBEXTWAR3YR-SP-03:C14 coupler
    • SURT6000RMXLI-BNDL uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Terminal

Side by side

Differences highlightedShow differences only (off)
Comparison of SURT1000RMXLI + WBEXTWAR3YR-SP-03, SURT6000RMXLI-BNDL
60 specifications
Features6 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers1 kVA6 kVA
Output powerDiffers700 W4200 W
WaveformSineSine
Input operation voltage (min)100 V100 V
Input operation voltage (max)280 V280 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (min)220 V220 V
Output operation voltage (max)240 V240 V
Surge energy ratingDiffers420 J555 J
EfficiencyDiffers89.1%92%
Crest factor3:13:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Noise levelDiffers50 dB55 dB
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Audible alarm(s)YesYes
Auto-restartYesYes
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Ports & interfaces4 differ
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Power plugDiffersC14 couplerTerminal
AC outlets quantityDiffers6 AC outlet(s)10 AC outlet(s)
Number of output IEC jumpersDiffers24
RS-232 ports11
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Battery1 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Number of battery cellsKnown for oneUnknown — not stated by the source2
Battery recharge timeDiffers3 h2.50 h
Hot-swap batteryYesYes
Automatic battery testYesYes
Cold startYesYes
Number of batteries supportedKnown for one1Unknown — not stated by the source
Typical backup time at full loadKnown for one7.6 minUnknown — not stated by the source
Typical backup time at half loadKnown for one19.7 minUnknown — not stated by the source
Design1 differ
Form factorRackmountRackmount
Product colourBlackBlack
Rack capacityDiffers2U3U
LED indicatorsYesYes
International Protection (IP) codeIP20IP20
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-20 - 50 °C-15 - 45 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Certificates1 differ
Compliance certificatesRoHSRoHS
CertificationDiffersC-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, VDEC-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, VDE REACH
Weight & dimensions3 differ
Width432 mm432 mm
DepthDiffers483 mm660 mm
HeightDiffers85 mm130 mm
WeightDiffers23 kg54.5 kg
Packaging data4 differ
Package widthDiffers630 mm603 mm
Package depthDiffers594 mm980 mm
Package heightDiffers286 mm347 mm
Package weightDiffers27.8 kg63.6 kg
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the sourceRBC44
Output connectionsKnown for oneUnknown — not stated by the source8 x C13 & 2 x C19
Nominal input voltageKnown for oneUnknown — not stated by the source230 V
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Number of phasesKnown for one1Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.