Key differences

  • Output power
    • SURT1000RMXLI + Service Bundle 3:700 W
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:550 W
  • Input frequency
    • SURT1000RMXLI + Service Bundle 3:45/65 Hz
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:50/60 Hz
  • Output voltage Total Harmonic Distortion (THD)
    • SURT1000RMXLI + Service Bundle 3:3%
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:5%
  • AC outlets quantity
    • SURT1000RMXLI + Service Bundle 3:6 AC outlet(s)
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:3 AC outlet(s)
  • Typical backup time at full load
    • SURT1000RMXLI + Service Bundle 3:7.6 min
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:1 min
  • Typical backup time at half load
    • SURT1000RMXLI + Service Bundle 3:19.7 min
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:6.5 min
  • Form factor
    • SURT1000RMXLI + Service Bundle 3:Rackmount
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:Tower
  • Width
    • SURT1000RMXLI + Service Bundle 3:432 mm
    • VALUE1000EILCD uninterruptible power supply (UPS) 1 kVA:100 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of SURT1000RMXLI + Service Bundle 3, VALUE1000EILCD
65 specifications
Features3 differ
UPS topologyKnown for oneDouble-conversion (Online)Unknown — not stated by the source
Output powerDiffers700 W550 W
Input operation voltage (min)Known for one100 VUnknown — not stated by the source
Input operation voltage (max)Known for one280 VUnknown — not stated by the source
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Known for one220 VUnknown — not stated by the source
Output operation voltage (max)Known for one240 VUnknown — not stated by the source
Surge energy ratingKnown for one420 JUnknown — not stated by the source
EfficiencyKnown for one89.1%Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Differs3%5%
Noise levelKnown for one50 dBUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Surge protection featuresKnown for oneUnknown — not stated by the sourceFax, Modem, Network, Telephone
Ports & interfaces1 differ
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
AC outlets quantityDiffers6 AC outlet(s)3 AC outlet(s)
Number of output IEC jumpersKnown for one2Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Serial ports quantityKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Battery2 differ
Typical backup time at full loadDiffers7.6 min1 min
Typical backup time at half loadDiffers19.7 min6.5 min
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source8.5 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Design1 differ
Form factorDiffersRackmountTower
Rack capacityKnown for one2UUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Display typeKnown for oneUnknown — not stated by the sourceLCD
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-20 - 50 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneC-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, VDEUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers432 mm100 mm
DepthDiffers483 mm300 mm
HeightDiffers85 mm140 mm
WeightDiffers23 kg5.6 kg
Packaging dataidentical
Package widthKnown for one630 mmUnknown — not stated by the source
Package depthKnown for one594 mmUnknown — not stated by the source
Package heightKnown for one286 mmUnknown — not stated by the source
Package weightKnown for one27.8 kgUnknown — not stated by the source
Bundled softwareKnown for oneUnknown — not stated by the sourcePowerPanel
Other featuresidentical
Number of phasesKnown for one1Unknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source230 V

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.