Product comparison · 2 uninterruptible power supplies (upss)

APC SURT10000XLI + WBEXTWAR3YR-SP-06 vs Vertiv Liebert Nfinity 8 Bay, 4kVA

Add a product
  • 20specifications compared
  • 15differ
  • 5identical
  • 45known for one product only

Key differences

The APC SURT10000XLI + WBEXTWAR3YR-SP-06 has 6 kVA more output power capacity than the Vertiv Liebert Nfinity 8 Bay, 4kVA (10 kVA vs 4 kVA). The APC SURT10000XLI + WBEXTWAR3YR-SP-06 has 5,200 W more output power than the Vertiv Liebert Nfinity 8 Bay, 4kVA (8000 W vs 2800 W). The APC SURT10000XLI + WBEXTWAR3YR-SP-06 has 50 V more input operation voltage (min) than the Vertiv Liebert Nfinity 8 Bay, 4kVA (160 V vs 110 V). Input frequency: 50/60 Hz on the APC SURT10000XLI + WBEXTWAR3YR-SP-06, 40/70 Hz on the Vertiv Liebert Nfinity 8 Bay, 4kVA. Form factor: Rackmount/Tower on the APC SURT10000XLI + WBEXTWAR3YR-SP-06, Tower on the Vertiv Liebert Nfinity 8 Bay, 4kVA.

  • Output power capacity
    • SURT10000XLI + WBEXTWAR3YR-SP-06:10 kVA
    • Liebert Nfinity 8 Bay, 4kVA:4 kVA
  • Output power
    • SURT10000XLI + WBEXTWAR3YR-SP-06:8000 W
    • Liebert Nfinity 8 Bay, 4kVA:2800 W
  • Input operation voltage (min)
    • SURT10000XLI + WBEXTWAR3YR-SP-06:160 V
    • Liebert Nfinity 8 Bay, 4kVA:110 V
  • Input operation voltage (max)
    • SURT10000XLI + WBEXTWAR3YR-SP-06:280 V
    • Liebert Nfinity 8 Bay, 4kVA:276 V
  • Input frequency
    • SURT10000XLI + WBEXTWAR3YR-SP-06:50/60 Hz
    • Liebert Nfinity 8 Bay, 4kVA:40/70 Hz
  • Output operation voltage (min)
    • SURT10000XLI + WBEXTWAR3YR-SP-06:220 V
    • Liebert Nfinity 8 Bay, 4kVA:120 V
  • Noise level
    • SURT10000XLI + WBEXTWAR3YR-SP-06:55 dB
    • Liebert Nfinity 8 Bay, 4kVA:62 dB
  • Battery recharge time
    • SURT10000XLI + WBEXTWAR3YR-SP-06:2.2 h
    • Liebert Nfinity 8 Bay, 4kVA:5 h

Side by side

Differences highlightedShow differences only (on)
Comparison of SURT10000XLI + WBEXTWAR3YR-SP-06, Liebert Nfinity 8 Bay, 4kVA
65 specifications
Features7 differ
UPS topologyKnown for oneDouble-conversion (Online)Unknown — not stated by the source
Output power capacityDiffers10 kVA4 kVA
Output powerDiffers8000 W2800 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (min)Differs160 V110 V
Input operation voltage (max)Differs280 V276 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output operation voltage (min)Differs220 V120 V
Output frequency regulationKnown for one47/63 HzUnknown — not stated by the source
Surge energy ratingKnown for one1265 JUnknown — not stated by the source
EfficiencyKnown for one91.6%Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one7%Unknown — not stated by the source
Noise levelDiffers55 dB62 dB
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlet typesKnown for oneC13 coupler, C19 coupler, TerminalUnknown — not stated by the source
Power plugKnown for oneTerminalUnknown — not stated by the source
AC outlets quantityKnown for one8 AC outlet(s)Unknown — not stated by the source
Number of output IEC jumpersKnown for one6Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Battery1 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of batteries supportedKnown for one4Unknown — not stated by the source
Battery recharge timeDiffers2.2 h5 h
Automatic battery testKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Design3 differ
Form factorDiffersRackmount/TowerTower
Rack capacityKnown for one6UUnknown — not stated by the source
Display typeDiffersLEDLCD
LED indicatorsDiffersYesWLAN
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Operational conditionsidentical
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificates1 differ
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationDiffersC-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, EN 60950, EN 61000-3-2, GOST, VDEFCC 15, IEEE C62.41
Weight & dimensions3 differ
WidthDiffers263 mm508 mm
DepthDiffers736 mm711 mm
HeightDiffers432 mm1041 mm
WeightKnown for one110.9 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one597 mmUnknown — not stated by the source
Package depthKnown for one991 mmUnknown — not stated by the source
Package heightKnown for one552 mmUnknown — not stated by the source
Package weightKnown for one129.1 kgUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL 1778, c-UL
Other featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceSNMP
Nominal input voltageKnown for oneUnknown — not stated by the source220 V
Nominal output voltageKnown for oneUnknown — not stated by the source120 V
Operating temperature (T-T)Known for oneUnknown — not stated by the source32 - 104 °F
Over current protectionKnown for oneUnknown — not stated by the sourceYes
Overload protectionKnown for oneUnknown — not stated by the sourceYes
Relative humidityKnown for oneUnknown — not stated by the source0 - 95%

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons